MD 100 Aluminium, powder reagents

Precise water control with proven and compact measuring system

  • High-precision optics
  • High accuracy and reproducibility through precision interference filter (5 nm)
  • Industry specific parameter combinations available

The MD 100 photometer is a convenient choice for testing up to 14 parameters on a single instrument, depending on the combination. The instrument has a simple user interface and is constructed for field use.  Several industry specific versions are available the combine all of the tests you need.

Note according to EU regulation 2019/1148
This product is regulated by Regulation (EU) 2019/1148: all suspicious transactions, and significant disappearances and thefts should be reported to the relevant national contact point. See https://ec.europa.eu/info/index_en

 

Part Number 276205

1 pc.

Add to quotation cart

Applications

  • Boiler Water
  • Cooling Water
  • Drinking Water Treatment
  • Raw Water Treatment
  • Waste Water Treatment

Product information

The MD 100 has several key features that make it a favorite among users.

  • Waterproof Design
    The IP 68 design of this instrument ensures that the MD 100 remains water tight for up to 1 hour at 0.1 meter.
    Don't worry about dropping the instrument into a body of water - it floats!
  • Accurate, Reproducible Results
    The optical system of the MD 100 utilizes LEDs and interference filters
    which quickly gives you results that you can be confident in. You always measure in the spectral peak.
  • User Calibration Mode
    A one-point calibration is possible. 
    Additionally, all MD 100 instruments have the ability to display readings directly in ABS or %T units.
  • One-time-Zero Function
    Don't waste time waiting for your instrument to Zero after each test.
    When testing a new sample, zero the instrument once and all subsequent tests of that sample do not require you to re-zero the instrument.
  • Automatic Data Storage with Transfer Capabilities
    The MD 100 automatically stores the last 16 readings with time and date stamp.
    These results can be transferred to a spreadsheet using the IRiM accessory.
  • Ergonomic Design
    Whether you're using the MD 100 out in the field or in the lab, the design of the instrument  makes it easy to handle and view the display.
    If you're using the instrument in the lab, the rubber feet on the bottom of the housing eliminates the need for two hand operation or to chase your instrument around the workbench.
  • Factory Programmed
    All MD 100 instruments are supplied ready to use with up to 14 calibration curves.
    All you need to do is select the test you need, prepare your sample and test!
  • Scroll Driven Menu System
    The simple interface allows you to quickly reach the test you need.
    When the instrument is turned on, it will automatically display the last test used.
  • 2-Year Warranty
Optics LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used. Wavelength specifications of interference filters:
430 nm Δλ = 5 nm
530 nm Δλ = 5 nm
560 nm Δλ = 5 nm
580 nm Δλ = 5 nm
610 nm Δλ = 6 nm
660 nm Δλ = 5 nm
Wavelength Accuracy ± 1
Photometric Range -2500 - 2500 mAbs
Photometric Accuracy 3 % FS (T = 20 °C – 25 °C)
Suitable Vials Round Cuvettes 24 mm
Display backlit LCD (on keypress)
Interfaces Infrared
Operation Foil keypad
Auto – OFF Yes
Calibration factory calibration and user calibration. Reset to factory calibration possible
Internal Storage internal ring memory for 16 data sets
Power Supply 4 micro batteries (AAA)
Battery Life Time approx. 17 hours
Clock Real Time Clock and Date
Portability Portable
Environmental Conditions Temperature:  5 - 40 °C rel. humidity: 30 - 90 % (non condensing)
Protection Class IP 68
Compliance CE
Dimensions 155 x 75 x 35 mm
Weight 260 g
Testparameter Measuring Range Method No. Chemical Method
Aluminium PP 0.01 - 0.25 mg/L Al M50 Eriochrom Cyanine R
Aluminium T 0.01 - 0.3 mg/L Al M40 Eriochrom Cyanine R
Title Measuring Range Chemical Method Packaging Unit Part Number Add to quotation cart
Aluminium No. 1 0.01 - 0.3 mg/L Al Eriochrom Cyanine R Tablet / 100 515460BT
Aluminium No. 1 0.01 - 0.3 mg/L Al Eriochrom Cyanine R Tablet / 250 515461BT
Aluminium No. 2 0.01 - 0.3 mg/L Al Eriochrom Cyanine R Tablet / 100 515470BT
Aluminium No. 2 0.01 - 0.3 mg/L Al Eriochrom Cyanine R Tablet / 250 515471BT
Set Aluminium No. 1/No. 2 100 Pc. 0.01 - 0.3 mg/L Al Eriochrom Cyanine R 100 each 517601BT
Set Aluminium No. 1/No. 2 250 Pc. 0.01 - 0.3 mg/L Al Eriochrom Cyanine R 250 each 517602BT
VARIO Aluminium Reagent, Set F20 0.01 - 0.25 mg/L Al Eriochrom Cyanine R 1 pc. 535000
Title Online Download Type Format Language Direct Download
Datasheet 276205 - MD 100 Aluminium, powder reagents Datasheet PDF (0.20 MB)
Instruction Manual MD 100, MD 110, MD 200 Instruction Manual PDF (12.01 MB)
Instruction Manual Single Method M40 - Aluminium T Procedure Single Method PDF (3.01 MB)
Instruction Manual Single Method M50 - Aluminium PP Procedure Single Method PDF (4.02 MB)
00386440 - MD1x0/200 - Aluminium PP, Aluminium T Handbook of Methods MD100/110/200 PDF (7.87 MB)
Declaration of Conformity md_100 Declaration of Conformity PDF (0.19 MB)
  • Instrument in plastic case
  • VARIO Aluminium ECR F20 PP
  • VARIO Hexamine F20
  • VARIO ECR Masking Reagent Solution
  • 4 micro batteries (AAA)
  • 3 round cuvettes (glass) with lid
  • Sealing rings
  • Stirring rod
  • Brush
  • Syringe (1 ml)
  • Syringe (10 ml)
  • Instruction manual
  • Quick Start Guide
  • Certificate (COC)
  • Warranty information
Title SDS Country Direct Download
Aluminium No_1
Aluminium No_2
Vario Aluminum ECR F20
Vario ECR-Masking RGT