MD 110 Chlorine, pH, Cyanuric acid, liquid reagents

Photometer with Bluetooth® Technology

  • Bluetooth® -Interface
  • Scroll Memory
  • Automatic switch-off
  • Calibration mode indicator

Bluetooth® function

All MD 110 photometers have a Bluetooth® function. To make the most of it, Tintometer offers an app for mobile devices as well as a PC software with dongle. The measurement results are transmitted to external devices via the Bluetooth® interface for quick evaluation and processing so that all data can be evaluated and assigned directly on site.

App AquaLX®

The free app AquaLX® is ideally designed for use in on-site measurements. Compatible with IOS®- and Android®-based smartphones and tablets, it enables uncomplicated data transmission. It maps all measured values ​​as an illustrative graphic with minimum and maximum limits and supports the export of the data as an Excel®-compatible CSV file.

PC Software

The PC software makes it possible to import data directly from the photometer to the Windows-based PC. As a stationary solution, it facilitates the transfer of data through a quickly established, permanently wireless connection. Further processing of the results can be done both in the software itself and by exporting the data to Excel or as a CSV file.
The set of software and Bluetooth® dongle is available as a separate accessory under item no. 2444480 available.

 

Part Number 2980152

1 pc.

Add to quotation cart

Applications

  • Boiler Water
  • Cooling Water
  • Disinfection Control
  • Drinking Water Treatment
  • Pool Water Control
  • Raw Water Treatment
  • Waste Water Treatment

Product information

The MD 110 has several key features that make it a favorite among users.

  • Waterproof Design
    The IP 68 design of this instrument ensures that the MD 110 remains water tight for up to 1 hour at 0.1 meter.  Don't worry about dropping the instrument into a body of water - it floats!
  • Accurate, Reproducible Results
    The optical system of the MD 110 utilizes LEDs and interference filters which quickly gives you results that you can be confident in.
  • User Calibration Mode
    A one-point calibration is possible.  Additionally, all MD 110 instruments have the ability to display readings directly in ABS or %T units.
  • One-time-Zero Function
    Don't waste time waiting for your instrument to Zero after each test.  When testing a new sample, zero the instrument once and all subsequent tests of that sample do not require you to re-zero the instrument.
  • Automatic Data Storage with Transfer Capabilities
    The MD 110 automatically stores the last 16 readings with time and date stamp.  These results can be transferred to a spreadsheet using the IRiM accessory.
  • Ergonomic Design
    Whether you're using the MD 110 out in the field or in the lab, the design of the instrument  makes it easy to handle and view the display.   If you're using the instrument in the lab, the rubber feet on the bottom of the housing eliminates the need for two hand operation or to chase your instrument around the workbench.
  • Factory Programmed
    All MD 110 instruments are supplied ready to use with up to 14 calibration curves.  All you need to do is select the test you need, prepare your sample and test!
  • Scroll Driven Menu System
    The simple interface allows you to quickly reach the test you need.  When the instrument is turned on, it will automatically display the last test used.
  • 2-Year Warranty
Optics LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used. Wavelength specifications of interference filters:
430 nm Δλ = 5 nm
530 nm Δλ = 5 nm
560 nm Δλ = 5 nm
580 nm Δλ = 5 nm
610 nm Δλ = 6 nm
660 nm Δλ = 5 nm
Wavelength Accuracy ± 1
Photometric Range -2500 - 2500 mAbs
Photometric Accuracy 3 % FS (T = 20 °C – 25 °C)
Display backlit LCD (on keypress)
Interfaces Bluetooth
Operation Foil keypad
Auto – OFF Yes
Calibration factory calibration and user calibration. Reset to factory calibration possible
Internal Storage internal ring memory for 125 data sets
Power Supply 4 micro batteries (AAA)
Battery Life Time approx. 17 hours
Clock Real Time Clock and Date
Portability Portable
Degree of Pollution 2
Maximum altitude above sea level 2000 m
Environmental Conditions temperature:  5 - 40 °C rel. humidity: 30 - 90 % (non condensing)
Protection Class IP 68
Compliance CE
Dimensions 155 x 75 x 35 mm
Weight 260 g
Testparameter Measuring Range Method No. Chemical Method
Chlorine HR T 0.1 - 10 mg/L Cl2 M103 DPD
Chlorine L 0.02 - 4.0 mg/L Cl2 M101 DPD
Chlorine T 0.01 - 6.0 mg/L Cl2 M100 DPD
CyA T 10 - 160 mg/L CyA M160 Melamine
pH value L 6.5 - 8.4 pH M331 Phenol Red
pH-value T 6.5 - 8.4 pH M330 Phenol Red
Title Measuring Range Chemical Method Packaging Unit Part Number Add to quotation cart
DPD No.1 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 100 511050BT
DPD No. 1 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 250 511051BT
DPD No. 1 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 500 511052BT
DPD No. 3 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 100 511080BT
DPD No. 3 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 250 511081BT
DPD No. 3 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 500 511082BT
DPD No. 1 High Calcium 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 100 515740BT
DPD No. 1 High Calcium 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 250 515741BT
DPD No. 1 High Calcium 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 500 515742BT
DPD No. 3 High Calcium 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 100 515730BT
DPD No. 3 High Calcium 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 250 515731BT
DPD No. 3 High Calcium 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 500 515732BT
DPD No. 4 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 100 511220BT
DPD No. 4 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 250 511221BT
DPD No. 4 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 500 511222BT
DPD No. 3 Evo 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 100 511420BT
DPD No. 3 Evo 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 250 511421BT
DPD No. 3 Evo 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 500 511422BT
DPD No. 4 Evo 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 100 511970BT
DPD No. 4 Evo 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 250 511971BT
DPD No. 4 Evo 0.01 - 6.0 mg/L Cl2 a) DPD Tablet / 500 511972BT
DPD 1 Buffer Solution, Blue Bottle 0.02 - 4.0 mg/L Cl2 a) DPD 15 mL 471010
DPD 1 Buffer Solution 0.02 - 4.0 mg/L Cl2 a) DPD 100 mL 471011
DPD 1 Buffer Solution 0.02 - 4.0 mg/L Cl2 a) DPD 1 pc. 471016
DPD 1 Reagent Solution, Green Bottle 0.02 - 4.0 mg/L Cl2 a) DPD 15 mL 471020
DPD 1 Reagent Solution 0.02 - 4.0 mg/L Cl2 a) DPD 100 mL 471021
DPD 1 Reagent Solution 0.02 - 4.0 mg/L Cl2 a) DPD 1 pc. 471026
DPD 3 Solution, Red Bottle 0.02 - 4.0 mg/L Cl2 a) DPD 15 mL 471030
DPD 3 Solution 0.02 - 4.0 mg/L Cl2 a) DPD 100 mL 471031
DPD 3 Solution 0.02 - 4.0 mg/L Cl2 a) DPD 1 pc. 471036
DPD Reagent Set 0.02 - 4.0 mg/L Cl2 a) DPD 1 pc. 471056
DPD No. 1 HR 0.1 - 10 mg/L Cl2 a) DPD Tablet / 100 511500BT
DPD No. 1 HR 0.1 - 10 mg/L Cl2 a) DPD Tablet / 250 511501BT
DPD No. 1 HR 0.1 - 10 mg/L Cl2 a) DPD Tablet / 500 511502BT
DPD No. 3 HR 0.1 - 10 mg/L Cl2 a) DPD Tablet / 100 511590BT
DPD No. 3 HR 0.1 - 10 mg/L Cl2 a) DPD Tablet / 250 511591BT
DPD No. 3 HR 0.1 - 10 mg/L Cl2 a) DPD Tablet / 500 511592BT
Set DPD No. 1 HR/No. 3 HR 100 Pc. 0.1 - 10 mg/L Cl2 a) DPD 100 each 517791BT
Set DPD No. 1 HR/No. 3 HR 250 Pc. 0.1 - 10 mg/L Cl2 a) DPD 250 each 517792BT
DPD No.3 HR Evo 0.1 - 10 mg/L Cl2 a) DPD Tablet / 100 511920BT
DPD No. 3 HR Evo 0.1 - 10 mg/L Cl2 a) DPD Tablet / 250 511921BT
DPD No. 3 HR Evo 0.1 - 10 mg/L Cl2 a) DPD Tablet / 500 511922BT
CyA-Test 10 - 160 mg/L CyA Melamine Tablet / 100 511370BT
CyA-Test 10 - 160 mg/L CyA Melamine Tablet / 250 511371BT
Deionised Water 10 - 160 mg/L CyA Melamine 100 mL 461275
Deionised Water 10 - 160 mg/L CyA Melamine 250 mL 457022
Phenol Red Photometer 6.5 - 8.4 pH Phenol Red Tablet / 100 511770BT
Phenol Red Photometer 6.5 - 8.4 pH Phenol Red Tablet / 250 511771BT
Phenol Red Photometer 6.5 - 8.4 pH Phenol Red Tablet / 500 511772BT
Phenol Red Solution 6.5 - 8.4 pH Phenol Red 15 mL 471040
Phenol Red Solution 6.5 - 8.4 pH Phenol Red 100 mL 471041
Phenol Red Solution in 6-pack 6.5 - 8.4 pH Phenol Red 1 pc. 471046
Title Part Number Add to quotation cart
ValidCheck Chlorine 1,5 mg/l 48105510
Service plan - 3 years for MD100/MD110/MD200 19802801
Fixed price service package for MD100/MD110/MD200 19802701
Micro batteries (AAA), set of 4 1950026
Measuring beaker, 100 ml 384801
Stirring rod, 13 cm length 364100
Stirring rod, 13 cm length, set of 10 364120
Stirring rod, 10 cm length 364109
Stirring rod, 10 cm length, set of 10 364130
Mixing cylinder, 25 ml 19802650
Membrane filter set for use when preparing samples, 25 membrane filters 0.45 µm, 2 syringes 20 ml 366150
Plastic funnel with handle (white) 471007
Brush, 11 cm length 380230
Water sampler with bottle 250 mL and lid, AF 631 170500
250 mL bottle, AF 631 375069
Round cuvette 24 mm ø, set of 12 197620
Round cuvette 24 mm ø, set of 5 197629
Round cuvette 16 mm ø, set of 10 197665
Multy cuvette-2, set of 12 197600
Cuvette stand for 6 round cuvettes Ø 24 mm 418951
Cuvette stand for 10 round cuvettes Ø 16 mm 418957
Adapter for round cuvettes 16 mm ø 19802190
Cleaning cloth 197635
Sealing ring for round vials 24 mm ø, set of 12 197626
Kit of BT data transfer software and Bluetooth Dongle 2444480
Reference Standard Kit Chlorine - 0.2 and 1.0 mg/l (MD 100/110/200) 275650
Reference Standard Kit Chlorine - 0.5 and 2.0 mg/l (MD 100/110/200) 275655
Reference Standard Kit Chlorine - 1.0 and 4.0 mg/l (MD 100/110/200) 275656
Reference Standard Kit pH - 7.45 (MD 100/110/200) 275670
Verification Standard Kit MD 100 / 200 215670
Additionally for each method 999855
Factory calibration certificate ISO 9001 for MD100/MD110/MD200 999750
Title Online Download Type Format Language Direct Download
Datasheet 2980152 - MD 110 Chlorine, pH, Cyanuric acid, liquid reagents Datasheet PDF (0.20 MB)
Instruction Manual MD 100, MD 110, MD 200 Instruction Manual PDF (12.01 MB)
Instruction Manual Single Method M100 - Chlorine T Procedure Single Method PDF (3.49 MB)
Instruction Manual Single Method M101 - Chlorine L Procedure Single Method PDF (3.48 MB)
Instruction Manual Single Method M103 - Chlorine HR T Procedure Single Method PDF (3.49 MB)
Instruction Manual Single Method M160 - CyA T Procedure Single Method PDF (3.00 MB)
Instruction Manual Single Method M330 - pH-value T Procedure Single Method PDF (2.98 MB)
Instruction Manual Single Method M331 - pH value L Procedure Single Method PDF (2.98 MB)
00386465 - MD1x0/200 - Chlorine HR T, Chlorine L, Chlorine T, CyA T, pH value L, pH-value T Handbook of Methods MD100/110/200 PDF (7.87 MB)
Information Bluetooth® Information Bluetooth PDF (0.02 MB)
EU-Declaration of Conformity MD 110 Declaration of Conformity PDF (0.13 MB)
Validation Data DPD No.1 Free Chlorine Validation Data PDF (0.12 MB)
  • Instrument in plastic case with 4 micro batteries (AAA)
  • DPD 1 Buffer Solution
  • DPD 1 Reagent Solution
  • DPD 3 Solution
  • Phenol Red Solution
  • 100 tablet reagents CyA-Test
  • 3 Round vials (glass) with lid and sealing rings
  • 1 Stirring rod
  • 1 Brush
  • Instruction manual
  • Manual of Methods
  • Certificate (COC)
  • Warranty information
Title SDS Country Direct Download
CyA-Test
DPD 1 Buffer solution
DPD 1 Reagent Solution
DPD 3 Reagent Solution
DPD No. 1
DPD No. 1 HR
DPD No. 1 High Calcium
DPD No. 3 EVO
DPD No. 3 HR
DPD No. 3 HR EVO
DPD No. 3 High Calcium
DPD No. 3 from Lot Code YA1E0132
DPD No. 4 EVO
DPD No. 4 from Lot Code YA2A0227
Phenol red Photometer
Phenol red Solution
Vario VE-Water
The Bluetooth®  word mark is a registered trademark owned by Bluetooth SIG, Inc. and any use by Lovibond® Tintometer GmbH is under license. IOS® is a registered trademark of Cisco, Inc. and licensed to Apple, Inc. Android™ is a trademark of Google, Inc.
Bluetooth®  is a wireless technology subject to regional approval. The use of Lovibond® instruments with Bluetooth® technology is currently only allowed in certain regions of the world. The use of the instruments will also be possible in other regions in the future. For current regions and further information, click here