MD 110 Chlorine, pH, Cyanuric acid, tablet reagents
Photometer with Bluetooth® Technology
- Bluetooth® -Interface
- Scroll Memory
- Automatic switch-off
- Calibration mode indicator
Bluetooth® function
All MD 110 photometers have a Bluetooth® function. To make the most of it, Tintometer offers an app for mobile devices as well as a PC software with dongle. The measurement results are transmitted to external devices via the Bluetooth® interface for quick evaluation and processing so that all data can be evaluated and assigned directly on site.
App AquaLX®
The free app AquaLX® is ideally designed for use in on-site measurements. Compatible with IOS®- and Android®-based smartphones and tablets, it enables uncomplicated data transmission. It maps all measured values as an illustrative graphic with minimum and maximum limits and supports the export of the data as an Excel®-compatible CSV file.
PC Software
The PC software makes it possible to import data directly from the photometer to the Windows-based PC. As a stationary solution, it facilitates the transfer of data through a quickly established, permanently wireless connection. Further processing of the results can be done both in the software itself and by exporting the data to Excel or as a CSV file.
The set of software and Bluetooth®
dongle is available as a separate accessory under item no. 2444480 available.
Part Number 2980102
Applications
- Boiler Water
- Cooling Water
- Disinfection Control
- Drinking Water Treatment
- Pool Water Control
- Raw Water Treatment
- Waste Water Treatment
Product information
The MD 110 has several key features that make it a favorite among users.
-
Waterproof Design
The IP 68 design of this instrument ensures that the MD 110 remains water tight for up to 1 hour at 0.1 meter. Don't worry about dropping the instrument into a body of water - it floats! -
Accurate, Reproducible Results
The optical system of the MD 110 utilizes LEDs and interference filters which quickly gives you results that you can be confident in. -
User Calibration Mode
A one-point calibration is possible. Additionally, all MD 110 instruments have the ability to display readings directly in ABS or %T units. -
One-time-Zero Function
Don't waste time waiting for your instrument to Zero after each test. When testing a new sample, zero the instrument once and all subsequent tests of that sample do not require you to re-zero the instrument. -
Automatic Data Storage with Transfer Capabilities
The MD 110 automatically stores the last 16 readings with time and date stamp. These results can be transferred to a spreadsheet using the IRiM accessory. -
Ergonomic Design
Whether you're using the MD 110 out in the field or in the lab, the design of the instrument makes it easy to handle and view the display. If you're using the instrument in the lab, the rubber feet on the bottom of the housing eliminates the need for two hand operation or to chase your instrument around the workbench. -
Factory Programmed
All MD 110 instruments are supplied ready to use with up to 14 calibration curves. All you need to do is select the test you need, prepare your sample and test! -
Scroll Driven Menu System
The simple interface allows you to quickly reach the test you need. When the instrument is turned on, it will automatically display the last test used. - 2-Year Warranty
Optics | LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used. Wavelength specifications of interference filters: 430 nm Δλ = 5 nm 530 nm Δλ = 5 nm 560 nm Δλ = 5 nm 580 nm Δλ = 5 nm 610 nm Δλ = 6 nm 660 nm Δλ = 5 nm |
Wavelength Accuracy | ± 1 |
Photometric Range | -2500 - 2500 mAbs |
Photometric Accuracy | 3 % FS (T = 20 °C – 25 °C) |
Display | backlit LCD (on keypress) |
Interfaces | Bluetooth |
Operation | Foil keypad |
Auto – OFF | Yes |
Calibration | factory calibration and user calibration. Reset to factory calibration possible |
Internal Storage | internal ring memory for 125 data sets |
Power Supply | 4 micro batteries (AAA) |
Battery Life Time | approx. 17 hours |
Clock | Real Time Clock and Date |
Portability | Portable |
Degree of Pollution | 2 |
Maximum altitude above sea level | 2000 m |
Environmental Conditions | temperature: 5 - 40 °C rel. humidity: 30 - 90 % (non condensing) |
Protection Class | IP 68 |
Compliance | CE |
Dimensions | 155 x 75 x 35 mm |
Weight | 260 g |
Testparameter | Measuring Range | Method No. | Chemical Method |
---|---|---|---|
Chlorine HR T | 0.1 - 10 mg/L Cl2 | M103 | DPD |
Chlorine L | 0.02 - 4.0 mg/L Cl2 | M101 | DPD |
Chlorine T | 0.01 - 6.0 mg/L Cl2 | M100 | DPD |
CyA T | 10 - 160 mg/L CyA | M160 | Melamine |
pH value L | 6.5 - 8.4 pH | M331 | Phenol Red |
pH-value T | 6.5 - 8.4 pH | M330 | Phenol Red |
Title | Measuring Range | Chemical Method | Packaging Unit | Part Number | Add to quotation cart |
---|---|---|---|---|---|
DPD No.1 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 511050BT |
|
DPD No. 1 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 511051BT |
|
DPD No. 1 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 511052BT |
|
DPD No. 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 511080BT |
|
DPD No. 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 511081BT |
|
DPD No. 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 511082BT |
|
DPD No. 1 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 515740BT |
|
DPD No. 1 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 515741BT |
|
DPD No. 1 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 515742BT |
|
DPD No. 3 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 515730BT |
|
DPD No. 3 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 515731BT |
|
DPD No. 3 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 515732BT |
|
DPD No. 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 511220BT |
|
DPD No. 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 511221BT |
|
DPD No. 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 511222BT |
|
DPD No. 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 511420BT |
|
DPD No. 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 511421BT |
|
DPD No. 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 511422BT |
|
DPD No. 4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 511970BT |
|
DPD No. 4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 511971BT |
|
DPD No. 4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 511972BT |
|
DPD 1 Buffer Solution, Blue Bottle | 0.02 - 4.0 mg/L Cl2 a) | DPD | 15 mL | 471010 |
|
DPD 1 Buffer Solution | 0.02 - 4.0 mg/L Cl2 a) | DPD | 100 mL | 471011 |
|
DPD 1 Buffer Solution | 0.02 - 4.0 mg/L Cl2 a) | DPD | 1 pc. | 471016 |
|
DPD 1 Reagent Solution, Green Bottle | 0.02 - 4.0 mg/L Cl2 a) | DPD | 15 mL | 471020 |
|
DPD 1 Reagent Solution | 0.02 - 4.0 mg/L Cl2 a) | DPD | 100 mL | 471021 |
|
DPD 1 Reagent Solution | 0.02 - 4.0 mg/L Cl2 a) | DPD | 1 pc. | 471026 |
|
DPD 3 Solution, Red Bottle | 0.02 - 4.0 mg/L Cl2 a) | DPD | 15 mL | 471030 |
|
DPD 3 Solution | 0.02 - 4.0 mg/L Cl2 a) | DPD | 100 mL | 471031 |
|
DPD 3 Solution | 0.02 - 4.0 mg/L Cl2 a) | DPD | 1 pc. | 471036 |
|
DPD Reagent Set | 0.02 - 4.0 mg/L Cl2 a) | DPD | 1 pc. | 471056 |
|
DPD No. 1 HR | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 100 | 511500BT |
|
DPD No. 1 HR | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 250 | 511501BT |
|
DPD No. 1 HR | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 500 | 511502BT |
|
DPD No. 3 HR | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 100 | 511590BT |
|
DPD No. 3 HR | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 250 | 511591BT |
|
DPD No. 3 HR | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 500 | 511592BT |
|
Set DPD No. 1 HR/No. 3 HR 100 Pc. | 0.1 - 10 mg/L Cl2 a) | DPD | 100 each | 517791BT |
|
Set DPD No. 1 HR/No. 3 HR 250 Pc. | 0.1 - 10 mg/L Cl2 a) | DPD | 250 each | 517792BT |
|
DPD No.3 HR Evo | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 100 | 511920BT |
|
DPD No. 3 HR Evo | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 250 | 511921BT |
|
DPD No. 3 HR Evo | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 500 | 511922BT |
|
CyA-Test | 10 - 160 mg/L CyA | Melamine | Tablet / 100 | 511370BT |
|
CyA-Test | 10 - 160 mg/L CyA | Melamine | Tablet / 250 | 511371BT |
|
Deionised Water | 10 - 160 mg/L CyA | Melamine | 250 mL | 457022 |
|
Phenol Red Photometer | 6.5 - 8.4 pH | Phenol Red | Tablet / 100 | 511770BT |
|
Phenol Red Photometer | 6.5 - 8.4 pH | Phenol Red | Tablet / 250 | 511771BT |
|
Phenol Red Photometer | 6.5 - 8.4 pH | Phenol Red | Tablet / 500 | 511772BT |
|
Phenol Red Solution | 6.5 - 8.4 pH | Phenol Red | 15 mL | 471040 |
|
Phenol Red Solution | 6.5 - 8.4 pH | Phenol Red | 100 mL | 471041 |
|
Phenol Red Solution in 6-pack | 6.5 - 8.4 pH | Phenol Red | 1 pc. | 471046 |
|
- Instrument in plastic case with 4 micro batteries (AAA)
- 100 tablet reagents DPD No.1
- 100 tablet reagents DPD No.3 Evo
- 100 tablet reagents Phenol Red Photometer
- 100 tablet reagents CyA-Test
- 3 Round vials (glass) with lid and sealing rings
- 1 Stirring rod
- 1 Brush
- Instruction manual
- Manual of Methods
- Certificate (COC)
- Warranty information
Bluetooth® is a wireless technology subject to regional approval. The use of Lovibond® instruments with Bluetooth® technology is currently only allowed in certain regions of the world. The use of the instruments will also be possible in other regions in the future. For current regions and further information, click here