MD 100 Photometer

Precise water control with proven and compact measuring system

  • High-precision optics
  • High accuracy and reproducibility through precision interference filter (5 nm)
  • Industry specific parameter combinations available

The MD 100 photometer is a convenient choice for testing up to 14 parameters on a single instrument, depending on the combination. The instrument has a simple user interface and is constructed for field use.  Several industry specific versions are available the combine all of the tests you need.

 

Applications

  • Boiler Water
  • Cooling Water
  • Disinfection Control
  • Drinking Water Treatment
  • Galvanization
  • Pool Water Control
  • Raw Water Treatment
  • Waste Water Treatment
Parameter Count Title Parameter and Range Part Number Add to quotation cart
Single
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with aluminium reagent tablets.
Aluminium PP 0.01 - 0.25 mg/L Al
Aluminium T 0.01 - 0.3 mg/L Al
276200
Single
The mobile photometer works with LEDs, interference filters and automatic storage. The measurement is performed with aluminium powder reagent.
Aluminium PP 0.01 - 0.25 mg/L Al
Aluminium T 0.01 - 0.3 mg/L Al
276205
Single
LEDs, interference filters, automatic storage: The mobile and ergonomic photometer works with ammonium reagent tablets.
Ammonia PP 0.01 - 0.8 mg/L N
Ammonia T 0.02 - 1 mg/L N
276060
Single
The mobile photometer works with LEDs, interference filters and automatic storage. The measurement is performed with ammonium powder reagent.
Ammonia PP 0.01 - 0.8 mg/L N
Ammonia T 0.02 - 1 mg/L N
276065
Single
LEDs, interference filters, automatic storage: The mobile and ergonomic photometer works with chlorine reagent tablets.
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
276000
Single
The mobile photometer works with LEDs, interference filters and automatic storage. The measurement is carried out with chlorine liquid reagent.
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
276005
Single
LEDs, interference filters, automatic storage: The mobile and ergonomic photometer works with reagent tablets for different types of chlorine.
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine PP 0.02 - 2 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
276020
Single
The mobile photometer works with LEDs, interference filters and automatic storage. Powder reagents determine different types of chlorine.
Chlorine HR PP 0.1 - 8 mg/L Cl2 a)
Chlorine PP 0.02 - 2 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
276025
Single
LEDs, interference filters, automatic storage: The mobile and ergonomic photometer works with powder reagent.
Chlorine HR PP 0.1 - 8 mg/L Cl2 a)
Chlorine PP 0.02 - 2 mg/L Cl2 a)
276010
Single
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with tablet reagents for HR chlorine.
Chlorine HR (KI) T 5 - 200 mg/L Cl2 276170
Single
The mobile photometer works with LEDs, interference filter and automatic storage. The measurement is carried out with chlorine dioxide reagent tablets.
Chlorine dioxide PP 0.04 - 3.8 mg/L ClO2
Chlorine dioxide T 0.02 - 11 mg/L ClO2
276030
Single
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with powder reagents for chlorine dioxide.
Chlorine dioxide PP 0.04 - 3.8 mg/L ClO2
Chlorine dioxide T 0.02 - 11 mg/L ClO2
276035
Single
The mobile photometer works with LEDs, interference filter and automatic storage. The measurement is performed with chloride reagent tablets.
Chloride T 0.5 - 25 mg/L Cl-
Chloride T 5 - 250 mg/L Cl- i)
276180
Single
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with tube tests for COD.
COD HR TT 200 - 15000 mg/L CODb)
COD LMR TT 15 - 300 mg/L CODb)
COD LR TT 3 - 150 mg/L CODb)
COD MR TT 20 - 1500 mg/L CODb)
276120
Single
The mobile photometer works with LEDs, interference filter and automatic storage. The measurement is performed with iron reagent tablets.
Iron (TPTZ) PP 0.02 - 1.8 mg/L Fe
Iron PP 0.02 - 3 mg/L Feg)
Iron T 0.02 - 1 mg/L Fe
276050
Single
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with powder reagents for iron TPTZ.
Iron (TPTZ) PP 0.02 - 1.8 mg/L Fe
Iron PP 0.02 - 3 mg/L Feg)
Iron T 0.02 - 1 mg/L Fe
276055
Single
The mobile photometer works with LEDs, interference filter and automatic storage. The measurement is performed with iron powder reagent.
Iron (TPTZ) PP 0.02 - 1.8 mg/L Fe
Iron PP 0.02 - 3 mg/L Feg)
Iron T 0.02 - 1 mg/L Fe
276056
Single
The mobile photometer works with LEDs, interference filters and automatic memory.
Fluoride L 0.05 - 2 mg/L F- 276090
Single
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with reagent tablets for total hardness.
Hardness total HR T 20 - 500 mg/L CaCO3 i)
Hardness total T 2 - 50 mg/L CaCO3
276190
Single
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with tablet reagents for urea.
Urea T 0.1 - 2.5 mg/L Urea
Urea T 0.2 - 5 mg/L Ureai)
276210
Single
The mobile photometer works with LEDs, interference filters and automatic storage. No reagent is required for the Hazen/A.P.H.A. check.
Hazen 24 10 - 500 mg/L Pt 276160
Single
LEDs, interference filters, automatic storage: The mobile and ergonomic photometer works with tablet reagents for copper.
Copper PP 0.05 - 5 mg/L Cu
Copper T 0.05 - 5 mg/L Cua)
276080
Single
The mobile photometer works with LEDs, interference filter and automatic storage. The measurement is performed with copper powder reagent.
Copper PP 0.05 - 5 mg/L Cu
Copper T 0.05 - 5 mg/L Cua)
276085
Single
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with tablet reagents for manganese LR.
Manganese HR PP 0.1 - 18 mg/L Mn
Manganese LR PP 0.01 - 0.7 mg/L Mn
Manganese T 0.2 - 4 mg/L Mn
276100
Single
The mobile photometer works with LEDs, interference filter and automatic storage. The measurement is performed with manganese LR powder reagent.
Manganese HR PP 0.1 - 18 mg/L Mn
Manganese LR PP 0.01 - 0.7 mg/L Mn
Manganese T 0.2 - 4 mg/L Mn
276105
Single
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with reagent powder for manganese HR.
Manganese HR PP 0.1 - 18 mg/L Mn
Manganese LR PP 0.01 - 0.7 mg/L Mn
Manganese T 0.2 - 4 mg/L Mn
276106
Single
The mobile photometer works with LEDs, interference filter, automatic storage. The molybdenum measurement is performed with reagent tablets and powders.
Molybdate HR PP 0.3 - 40 mg/L Mo
Molybdate LR PP 0.03 - 3 mg/L Mo
Molybdate T 0.6 - 50 mg/L MoO4
276140
Single
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with reagent powder for molybdenum HR.
Molybdate HR PP 0.3 - 40 mg/L Mo
Molybdate LR PP 0.03 - 3 mg/L Mo
Molybdate T 0.6 - 50 mg/L MoO4
276141
Single
The mobile photometer works with LEDs, interference filter, automatic storage. The molybdenum measurement is performed with tablet reagents.
Molybdate HR PP 0.3 - 40 mg/L Mo
Molybdate LR PP 0.03 - 3 mg/L Mo
Molybdate T 0.6 - 50 mg/L MoO4
276142
Single
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with tablet reagents for phosphate.
Phosphate LR T 0.02 - 1.3 mg/L P
Phosphate PP 0.02 - 0.8 mg/L P
276040
Single
The mobile photometer works with LEDs, interference filter, automatic storage. The phosphate measurement is performed with powder reagent.
Phosphate LR T 0.02 - 1.3 mg/L P
Phosphate PP 0.02 - 0.8 mg/L P
276045
Single
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with tablet reagents for silicate.
Silicate HR PP 1 - 90 mg/L SiO2
Silicate LR PP 0.1 - 1.6 mg/L SiO2
Silicate T 0.05 - 4 mg/L SiO2
276110
Single
The mobile photometer works with LEDs, interference filter, automatic storage. The silicate LR measurement is performed with powder reagent.
Silicate HR PP 1 - 90 mg/L SiO2
Silicate LR PP 0.1 - 1.6 mg/L SiO2
Silicate T 0.05 - 4 mg/L SiO2
276115
Single
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with powder reagent for silicate HR.
Silicate HR PP 1 - 90 mg/L SiO2
Silicate LR PP 0.1 - 1.6 mg/L SiO2
Silicate T 0.05 - 4 mg/L SiO2
276116
Single
The mobile photometer works with LEDs, interference filters, automatic storage. No reagent is necessary for the measurement.
Suspended solids 24 10 - 750 mg/L TSS 276150
2in1
LEDs, interference filters, automatic storage: The mobile and ergonomic photometer works with reagent tablets for chlorine and pH.
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278020
2in1
The mobile photometer works with LEDs, interference filter, automatic storage. The chlorine/pH measurement is carried out with liquid reagents.
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278025
2in1
The mobile photometer works with LEDs, interference filter, automatic storage. The chlorine measurement is carried out with powder reagents.
Chlorine HR PP 0.1 - 8 mg/L Cl2 a)
Chlorine PP 0.02 - 2 mg/L Cl2 a)
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278030
3in1
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with reagent tablets for chlorine, pH and cyanuric acid.
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
CyA T 10 - 160 mg/L CyA
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278010
3in1
The mobile photometer works with LEDs, interference filter, automatic storage. The chlorine/pH measurement is performed with liquid reagents.
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
CyA T 10 - 160 mg/L CyA
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278015
3in1
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with reagent tablets for chlorine, pH and alkalinity-m.
Alkalinity-m T 5 - 200 mg/L CaCO3
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278060
3in1
The mobile photometer works with LEDs, interference filter, automatic storage. The measurement is performed with liquid reagents.
Alkalinity-m T 5 - 200 mg/L CaCO3
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278065
2in1
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with tablet reagents for chlorine LR, chlorine HR and chlorine dioxide.
Chlorine dioxide T 0.02 - 11 mg/L ClO2
Chlorine HR (KI) T 5 - 200 mg/L Cl2
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
278000
4in1
The mobile photometer works with LEDs, interference filter, automatic storage. Chlorine, pH, cyanuric acid, alkalinity-m.
Alkalinity-m T 5 - 200 mg/L CaCO3
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
CyA T 10 - 160 mg/L CyA
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278070
4in1
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer measures chlorine and pH (liquid), cyanuric acid, alkalinity-m.
Alkalinity-m T 5 - 200 mg/L CaCO3
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
CyA T 10 - 160 mg/L CyA
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278075
4in1
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer measures chlorine DUO, chlorine, pH, alkalinity-m, calcium hardness.
Alkalinity-m T 5 - 200 mg/L CaCO3
Chlorine HR (KI) T 5 - 200 mg/L Cl2
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine MR PP 0.02 - 3.5 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
Hardness Calcium (B) T 20 - 500 mg/L CaCO3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278160
5in1
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer measures chlorine, pH, cyanuric acid, alkalinity-m, calcium hardness.
Alkalinity-m T 5 - 200 mg/L CaCO3
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
CyA T 10 - 160 mg/L CyA
Hardness Calcium (B) T 20 - 500 mg/L CaCO3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278080
6in1
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer measures chlorine, bromine, pH, cyanuric acid, alkalinity-m, calcium hardness.
Alkalinity-m T 5 - 200 mg/L CaCO3
Bromine T 0.05 - 13 mg/L Br2
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
CyA T 10 - 160 mg/L CyA
Hardness Calcium (B) T 20 - 500 mg/L CaCO3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278090
Boiler Water
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer measures 10 parameters from aluminium to silicate.
Aluminium PP 0.01 - 0.25 mg/L Al
Chloride L (B) 0.5 - 20 mg/L Cl-
Copper T 0.05 - 5 mg/L Cua)
DEHA PP 0.02 - 0.5 mg/L DEHA
Hydrazine P 0.05 - 0.5 mg/L N2H4
Iron LR L (A) 0.03 - 2 mg/L Fe
Oxygen dissolved C 10 - 800 µg/L O2 c)
Phosphate HR L 5 - 80 mg/L PO4
Polyacrylate L 1 - 30 mg/L Polyacryl
Silicate HR PP 1 - 90 mg/L SiO2
276230
Cooling Water
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer measures 10 parameters from aluminium to zinc.
16 Parameters 276240
Title Online Download Type Format Language Direct Download
Data Acquisition Software Utility Program ZIP (124.72 MB)
Declaration of Conformity md_100 Declaration of Conformity PDF (0.19 MB)