In order to give you a better service Tintometer uses cookies. By continuing to browse the site you are agreeing to our use of cookies.

Chlorine with liquid reagent

0.02 - 4.0 mg/l Cl2 a) Mark as favourite

Chlorine
Chlorine is the most popular and widely used of the disinfectants. The chlorination of water supplies, swimming pools and cooling tower waters are but a few of the everyday applications.

Free Chlorine (hypochlorous acid) reacts with Ammonia and certain Nitrogenous compounds to form Combined Chlorine. With Ammonia, the reaction produces chloramines which have very little disinfecting power, thus it is important to be able to determine the various fractions of Chlorine present at any one time.

DPD (NN Diethyl p Phenylene Diamine Sulphate) is the preferred reagent for the determination of Free, Combined and Total Chlorine. It is available in Tablet, Liquid and Powder form. A list of compatible instrumentation and test kits can be found below.

Total Chlorine can also be measured using a Potassium Iodide reagent. This can measure concentrations of up to 300 mg/l chlorine and is widely used in food manufacturing and industrial water treatment.

Applications

  • Boiler Water
  • Cooling Water
  • Disinfection Control
  • Drinking Water Treatment
  • Pool Water Control
  • Pool Water Treatment
  • Raw Water Treatment
  • Waste Water Treatment
Parameter Count Title Parameter and Range Part Number Mark as favourite
Single
LEDs, interference filters, automatic storage: The mobile and ergonomic photometer works with chlorine reagent tablets.
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
276000
Single
The mobile photometer works with LEDs, interference filters and automatic storage. The measurement is carried out with chlorine liquid reagent.
Chlorine L 0.02 - 4.0 mg/l Cl2 a) 276005
Single
LEDs, interference filters, automatic storage: The mobile and ergonomic photometer works with reagent tablets for different types of chlorine.
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
276020
2in1
LEDs, interference filters, automatic storage: The mobile and ergonomic photometer works with reagent tablets for chlorine and pH.
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278020
2in1
The mobile photometer works with LEDs, interference filter, automatic storage. The chlorine/pH measurement is carried out with liquid reagents.
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
pH value L 6.5 - 8.4
278025
3in1
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with reagent tablets for chlorine, pH and cyanuric acid.
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278010
3in1
The mobile photometer works with LEDs, interference filter, automatic storage. The chlorine/pH measurement is performed with liquid reagents.
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
pH value L 6.5 - 8.4
278015
3in1
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with reagent tablets for chlorine, pH and alkalinity-m.
Alkalinity-m T 5 - 200 mg/l CaCO3
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278060
3in1
The mobile photometer works with LEDs, interference filter, automatic storage. The measurement is performed with liquid reagents.
Alkalinity-m T 5 - 200 mg/l CaCO3
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
pH value L 6.5 - 8.4
278065
2in1
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with tablet reagents for chlorine LR, chlorine HR and chlorine dioxide.
Chlorine dioxide T 0.02 - 11 mg/l ClO2
Chlorine HR (KI) T (105) 5 - 200 mg/l Cl2
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
278000
4in1
The mobile photometer works with LEDs, interference filter, automatic storage. Chlorine, pH, cyanuric acid, alkalinity-m.
Alkalinity-m T 5 - 200 mg/l CaCO3
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278070
4in1
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer measures chlorine and pH (liquid), cyanuric acid, alkalinity-m.
Alkalinity-m T 5 - 200 mg/l CaCO3
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
pH value L 6.5 - 8.4
278075
4in1
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer measures chlorine DUO, chlorine, pH, alkalinity-m, calcium hardness.
Alkalinity-m T 5 - 200 mg/l CaCO3
Chlorine HR (KI) T (105) 5 - 200 mg/l Cl2
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine MR PP 0.02 - 3.5 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
Hardness Calcium (B) T 20 - 500 mg/l CaCO3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278160
5in1
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer measures chlorine, pH, cyanuric acid, alkalinity-m, calcium hardness.
Alkalinity-m T 5 - 200 mg/l CaCO3
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
Hardness Calcium (B) T 20 - 500 mg/l CaCO3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278080
6in1
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer measures chlorine, bromine, pH, cyanuric acid, alkalinity-m, calcium hardness.
Alkalinity-m T 5 - 200 mg/l CaCO3
Bromine T 0.05 - 13 mg/l Br2
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
Hardness Calcium (B) T 20 - 500 mg/l CaCO3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278090
Cooling Water
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer measures 10 parameters from aluminium to zinc.
16 Parameters 276240
3in1
Mobile water analysis: Evaluate, process and transmit your measured values via app directly on site. The measurement of Cl/pH/CyA is performed with tablet reagents.
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
2980102
3in1
Stay mobile: Evaluate, process and transmit your analysis results directly on site via app. Cl/pH/CyA is tested with liquid reagents.
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
pH value L 6.5 - 8.4
2980152
4in1
Mobile water analysis: Evaluate, process and transmit your measured values via app on site. Cl/pH/CyA/alkalinity-m is measured with tablet reagents.
Alkalinity-m T 5 - 200 mg/l CaCO3
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
2980702
4in1
Stay mobile: Evaluate, process and transmit your analysis results directly on site via app. Cl/pH/CyA/alkalinity-m is tested with liquid reagents.
Alkalinity-m T 5 - 200 mg/l CaCO3
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
pH value L 6.5 - 8.4
2980752
6in1
Evaluate, process and transmit your measured values via app on site. The measurement of Cl/bromine/pH/CyA/alkalinity-m/Calcium hardness is performed with tablet reagents.
Alkalinity-m T 5 - 200 mg/l CaCO3
Bromine T 0.05 - 13 mg/l Br2
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
Hardness Calcium (B) T 20 - 500 mg/l CaCO3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
2980902
Cooling Water
Evaluate, process and transmit your analysis results via app directly on site. Tested are 16 parameters from aluminium to zinc.
16 Parameters 2962402
2in1
Measuring instrument for precise results with low-maintenance technology in all areas of water analysis. The Cl/pH test is performed with tablet reagents.
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
2889402
2in1
With the low-maintenance instrument you achieve precise results in all areas of water analysis. Liquid reagents can be used for the Cl/pH test
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
pH value L 6.5 - 8.4
2889412
3in1
Measuring instrument for precise results with low-maintenance technology in all areas of water analysis. The Cl/pH/bromine test is carried out with tablet reagents.
Bromine T 0.05 - 13 mg/l Br2
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
2861802
3in1
With the low-maintenance instrument you achieve precise results in all areas of water analysis. Tablet reagents can be used for the Cl/pH/CyA test.
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
2860102
3in1
Measuring instrument for precise results with low-maintenance technology in all areas of water analysis. The Cl/pH test is performed with liquid reagents.
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
pH value L 6.5 - 8.4
2882002
3in1
With the low-maintenance instrument you achieve precise results in all areas of water analysis. Tablet reagents can be used for the Cl/pH/acid capacity test.
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
KS4.3 T 0.1 - 4 mmol/l KS4.3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
2889012
3in1
Measuring instrument for precise results with low-maintenance technology in all areas of water analysis. The Cl/pH test is performed with liquid reagents.
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
KS4.3 T 0.1 - 4 mmol/l KS4.3
pH value L 6.5 - 8.4
2889202
3in1
With the low-maintenance instrument you achieve precise results in all areas of water analysis. Tablet reagents can be used for the Cl/pH/alkalinity m-test.
Alkalinity-m T 5 - 200 mg/l CaCO3
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
2889002
3in1
Measuring device for precise results with low-maintenance technology in all areas of water analysis. The Cl/pH test is performed with liquid reagents.
Alkalinity-m T 5 - 200 mg/l CaCO3
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
pH value L 6.5 - 8.4
2889302
4in1
With the low-maintenance device you achieve precise results in all areas of water analysis. Tablet reagents can be used for the Cl/pH/CyA/acid capacity test.
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
KS4.3 T 0.1 - 4 mmol/l KS4.3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
2860512
4in1
Measuring instrument for precise results with low-maintenance technology in all areas of water analysis. The Cl/pH test is performed with liquid reagents.
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
KS4.3 T 0.1 - 4 mmol/l KS4.3
pH value L 6.5 - 8.4
2860522
4in1
With the low-maintenance instrument you achieve precise results in all areas of water analysis. Tablet reagents can be used for the Cl/pH/CyA/Alkalität-m-Test.
Alkalinity-m T 5 - 200 mg/l CaCO3
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
2860502
4in1
Measuring instrument for precise results with low-maintenance technology in all areas of water analysis. The Cl/pH test is performed with liquid reagents.
Alkalinity-m T 5 - 200 mg/l CaCO3
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
pH value L 6.5 - 8.4
2860542
4in1
With the low-maintenance device you achieve precise results in all areas of water analysis. Tablet reagents are provided for the Cl/pH/acid capacity/urea test.
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
KS4.3 T 0.1 - 4 mmol/l KS4.3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
Urea T 0.1 - 2.5 mg/l Urea
2862912
4in1
Measuring instrument for precise results with low-maintenance technology in all areas of water analysis with tablet reagents for Cl/ClO2pH/acid capacity.
Chlorine dioxide T 0.02 - 11 mg/l ClO2
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
KS4.3 T 0.1 - 4 mmol/l KS4.3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
2863802
5in1
With this low-maintenance instrument you can achieve precise results in all areas of water analysis with tablet reagents for Cl/pH/CyA/acid capacity/calcium hardness.
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
Hardness Calcium (B) T 20 - 500 mg/l CaCO3
KS4.3 T 0.1 - 4 mmol/l KS4.3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
2861212
5in1
Instrument for precise results with low-maintenance technology in all areas of water analysis with tablet reagents for Cl/pH/CyA/alkalinity-m/Calcium hardness.
Alkalinity-m T 5 - 200 mg/l CaCO3
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
Hardness Calcium (B) T 20 - 500 mg/l CaCO3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
2861202
6in1
With the low-maintenance instrument you achieve precise results in all areas of water analysis with tablet reagents for Cl/bromine/pH/CyA/acid capacity/calcium hardness.
Bromine T 0.05 - 13 mg/l Br2
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
Hardness Calcium (B) T 20 - 500 mg/l CaCO3
KS4.3 T 0.1 - 4 mmol/l KS4.3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
2861912
6in1
Instrument for precise results with low-maintenance technology in all areas of water analysis with tablet reagents for Cl/bromine/pH/CyA/alkalinity-m/Calcium hardness.
Alkalinity-m T 5 - 200 mg/l CaCO3
Bromine T 0.05 - 13 mg/l Br2
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
CyA T 10 - 160 mg/l CyA
Hardness Calcium (B) T 20 - 500 mg/l CaCO3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
2861902
6in1
With the low-maintenance instrument you achieve precise results in all areas of water analysis with tablet reagents for Cl/pH/CyA/alkalinity-m/copper/iron.
Alkalinity-m T 5 - 200 mg/l CaCO3
Chlorine HR T 0.1 - 10 mg/l Cl2 a)
Chlorine L 0.02 - 4.0 mg/l Cl2 a)
Chlorine T 0.01 - 6.0 mg/l Cl2 a)
Copper T 0.05 - 5 mg/l Cua)
CyA T 10 - 160 mg/l CyA
Iron T 0.02 - 1 mg/l Fe
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
2862102
Don't search any further: The MD 600 photometer series from Lovibond® covers all important parameters of water analysis under laboratory conditions.
114 Parameters 214020
Don't search any further: The MD 600 photometer series from Lovibond® covers all important parameters of water analysis under laboratory conditions.
114 Parameters 214025
Don't search any further: The MD 600 photometer series from Lovibond® covers all important parameters of water analysis under laboratory conditions.
117 Parameters 214140
50in1
a contemporay, microprocessor-controlled photometer
98 Parameters 210000-B
50in1
a contemporay, microprocessor-controlled photometer
98 Parameters 210000
22in1
The ultimate range in Pool Photometers for reliable pool relevant water analysis
35 Parameters 214065
22in1
The ultimate range in Pool Photometers for reliable pool relevant water analysis
35 Parameters 214070
Simplify your Work - Save Time and Money!
154 Parameters 71307000
Simplify your Work - Save Time and Money!
155 Parameters 71307500
Title Method No. Packaging Unit Part Number Mark as favourite
DPD 1 Buffer Solution, Blue Bottle M101 , M3114 , M3115 , M3116 , M3117 , M3118 , M3119 , M3120 , M3121 , M3122 , M3123 15 ml 471010
DPD 1 Buffer Solution M101 , M3114 , M3115 , M3116 , M3117 , M3118 , M3119 , M3120 , M3121 , M3122 , M3123 100 ml 471011
DPD 1 Buffer Solution M101 , M3114 , M3115 , M3116 , M3117 , M3118 , M3119 , M3120 , M3121 , M3122 , M3123 1 pc. 471016
DPD 1 Reagent Solution, Green Bottle M101 , M3114 , M3115 , M3116 , M3117 , M3118 , M3119 , M3120 , M3121 , M3122 , M3123 15 ml 471020
DPD 1 Reagent Solution M101 , M3114 , M3115 , M3116 , M3117 , M3118 , M3119 , M3120 , M3121 , M3122 , M3123 100 ml 471021
DPD 1 Reagent Solution M101 , M3114 , M3115 , M3116 , M3117 , M3118 , M3119 , M3120 , M3121 , M3122 , M3123 1 pc. 471026
DPD 3 Solution, Red Bottle M101 , M3114 , M3115 , M3116 , M3117 , M3118 , M3119 , M3120 , M3121 , M3122 , M3123 15 ml 471030
DPD 3 Solution M101 , M3114 , M3115 , M3116 , M3117 , M3118 , M3119 , M3120 , M3121 , M3122 , M3123 100 ml 471031
DPD 3 Solution M101 , M3114 , M3115 , M3116 , M3117 , M3118 , M3119 , M3120 , M3121 , M3122 , M3123 1 pc. 471036
DPD Reagent Set M101 , M3114 , M3115 , M3116 , M3117 , M3118 , M3119 , M3120 , M3121 , M3122 , M3123 1 pc. 471056
Title Online Download Type Format Language Direct Download
使用说明书 单一方法 M101 - Chlorine L Instruction Manual PDF (0.83 MB)
Title SDS Country Direct Download
DPD 1 Buffer solution
DPD 1 Reagent Solution
DPD 3 Reagent Solution