In order to give you a better service Tintometer uses cookies. By continuing to browse the site you are agreeing to our use of cookies.

PTV 2000 with Modbus and Bluetooth

Next Generation of On-line Turbidity Measurement

Mark as favourite

Part Number 6145694

Highlights

  • Smart Interface - Rethink the Controller
  • Simplified and Streamlined Processes
  • Innovative, Low Maintenance Design
  • Unsurpassed Accuracy for low-level effluent measurement

Turbidity is the key measurement parameter for determining drinking water quality.  

To develop this instrument, Lovibond® Tintometer® assembled a team of globally recognized turbidity experts.  We tasked them with creating a new process instrument that addresses all of the issues customers struggle with while using their current turbidity systems. These advancements, along with the addition of state-of-the-art communications and user interface make the PTV 1000 and PTV 2000 the next generation of process turbidimeters.

For further information, films and interactive view go to PTV MICROSITE >>

  • Process Simplified - A New Approach
    Details matter. The development of the PTV Series considered every aspect of process turbidity workflow - from installation and setup; daily measurement and control; routine procedures such as calibration, verification and maintenance; to data collection and management.
  • Smart User Interface - Rethink the Controller
    We’ve replaced the need for a traditional controller with the familiar interface of a smart device. By utilizing a mobile device app, the user experience is enhanced by allowing quick and easy data viewing, calculation of statistics and access to operator instructions and useful tips.
  • Designed to Save
    Save time, money and water by using the PTV system. These instruments are optimised for drinking water applications with unsurpassed low range accuracy (below 1 NTU). It has a variety of features that help users save.
  • Regulatory Compliant
    The PTV Series has instruments that meet EPA and ISO regulatory requirements.
  • Fluidics Manager
    The Fluidics Manager is an additional accessory that streamlines sample flowing into and out of the instrument. This eliminates the need to install and maintain separate devices to control sample entering and exiting the sensor.  
  • Panel Mounting System
    A Place for Everything. The Panel Mount is an additional accessory that aids in the installation of key instrument components and accessories.
  • Two Ways to Interface
    Touchscreen Interface - All PTV Series instruments are supplied with an integrated touchscreen. All measurement settings and routine functions such as calibration can be managed directly with the touchscreen without the need for additional devices.
    AquaLXP™ Interface - The AquaLXPTM app is an enhanced version of the touchscreen. In addition to being able to perform all of the functions as the touchscreen, users have access to animated instructions of all procedures, advanced data analysis and statistics tools, complete maintenance and repair logs as well as the comfort of using a familiar device.
  • Wet Standards - for Calibration & Verification
    T-CAL Turbidity Standards from Lovibond® Tintometer® are primary standards that are US EPA and ISO compliant.  
    When you combine our T-CAL Turbidity Standards and our T-CALplus™ packaging, turbidity standards have never been easier to use. 
Light Source LED (red light)
Power Requirements 90 to 264 VAC, 50/60 Hz. Auto Select
Accuracy ±2 Percent of reading or smaller 0.008 / 8 mNTU
Stray Light smaller 0.008 / 8 mNTU
Displayed Resolution up to 0.0001 NTU (range dependent) or 5 digits displayed
Repeatability / Precision better than 1% at 1 NTU
Initial Response 10 % change: 15 seconds @ max flow
Step Response T-90
Signal Averaging User Selectable: 1, 3, 6, 10, 30, 60, and 90 seconds, defaulted to 30 seconds
Sample Temperature 0 - 50 °C max sample temperature: 70 °C
Calibration One Point Calibration at 5.0 or 20 NTU with any regulatory approved formazin
Sample Flow 30 to 500 ml/min, optimal flow: 50 to 80 ml/min
Interfaces Bluetooth
Sample Inlet Connection 1/4-inch NPT female, 1/4-inch compression fitting tubing (included)
Sample Outlet (Drain) Connection 3/8-inch NPT female, 3/8-inch hose barb tubing (included)
Sample Inlet Tubing 1/4-inch OD or 6 mm OD
Sample Oulet Tubing 3/8-inch OD or 9 mm OD
Turbidimeter Body Drain Quick connect with integrated check valve
Analog Output: Measurement Module 1 selectable 0 - 20 mA or 4 - 20 mA; output span programmable over any portion of the measurement range
Analog Output: Junction Box 1 selectable 0 - 20 mA or 4 - 20 mA; output span programmable over any portion of the measurement range
Alarms Three set-point alarms, each equipped with an SPDT relay with unpowered contacts rated 5 A resistive load at 230 V, AC
Digital protocol Modbus
Enclosure Type: Junction Box Fiber reinforced polyester
Enclosure Rating: Junction Box IP 66
Measuring Range 0.0001 - 100 NTU
Safety Listed by TÜV Rheinland to UL 61010A-1: Certified by TÜV Rheinland to CSAC22.2 No. 1010.1: CE Certified by TÜV Rheinland to EN 61010-1
Immunity CE certified by TÜV Rheinland to EN 61326 (Industrial Levels)
Emissions Class A: EN 61326, CISPR 11, FCC Part 15, Canadian Interference-Causing Equipment Regulation ICES-003
Mounting Hardware Turbidimeter Sensor - Slotted Mounting Bracket that can be affixed to any vertical surface or panel (Optional). Junction Box - Direct mounting to any vertical surface or panel (Optional)
Method of Verification Wet Standards or dry verification device
Limit of Determination 0 NTU
Limit of Detection 0 NTU
Flow Indicator false
Portability Process
Environmental Conditions 5 - 50 °C, rel. humidity 5 - 95 % (Non-condensing)
Compliance EPA
Protection Class IP 65
Dimensions 158.5 x 340.4 x 334.5 mm
Weight 5 kg
Title Online Download Type Format Language Direct Download
Datasheet 6145694 - PTV 2000 with Modbus and Bluetooth Datasheet PDF (0.20 MB)
Instruction Manual PTV series Instruction Manual PDF (3.43 MB)
Instruction Manual Junction Box Instruction Manual PDF (5.57 MB)
PTV Firmware Software ZIP (44.22 MB)
EU-Declaration of Conformity PTV series Bluetooth Declaration of Conformity PDF (0.19 MB)
The Bluetooth®  word mark is a registered trademark owned by Bluetooth SIG, Inc. and any use by Lovibond® Tintometer GmbH is under license. IOS® is a registered trademark of Cisco, Inc. and licensed to Apple, Inc. Android™ is a trademark of Google, Inc.
Bluetooth®  is a wireless technology subject to regional approval. The use of Lovibond® instruments with Bluetooth® technology is currently only allowed in certain regions of the world. The use of the instruments will also be possible in other regions in the future. For current regions and further information, click here