MD 100 Boiler Water

Precise water control with proven and compact measuring system

  • High-precision optics
  • High accuracy and reproducibility through precision interference filter (5 nm)
  • Industry specific parameter combinations available
Most faults in steam production plants occur as a result of deficient monitoring and control of the boiler water. This includes, in particular, the formation of scale, corrosion and local overheating. Therefore, a regular treatment and testing protocol of the boiler water is critical. By using the MD 100 Boiler Water colorimeter system, you have an overview of the key parameters of your boiler water and can perform purposeful water treatment at all times.

 

Part Number 276230

1 pc.

Add to quotation cart

Applications

  • Boiler Water
  • Cooling Water
  • Drinking Water Treatment
  • Galvanization
  • Pool Water Control
  • Raw Water Treatment
  • Waste Water Treatment

Product information

The MD 100 has several key features that make it a favorite among users.

  • Waterproof Design
    The IP 68 design of this instrument ensures that the MD 100 remains water tight for up to 1 hour at 0.1 meter.
    Don't worry about dropping the instrument into a body of water - it floats!
  • Accurate, Reproducible Results
    The optical system of the MD 100 utilizes LEDs and interference filters
    which quickly gives you results that you can be confident in. You always measure in the spectral peak.
  • User Calibration Mode
    A one-point calibration is possible. 
    Additionally, all MD 100 instruments have the ability to display readings directly in ABS or %T units.
  • One-time-Zero Function
    Don't waste time waiting for your instrument to Zero after each test.
    When testing a new sample, zero the instrument once and all subsequent tests of that sample do not require you to re-zero the instrument.
  • Automatic Data Storage with Transfer Capabilities
    The MD 100 automatically stores the last 16 readings with time and date stamp.
    These results can be transferred to a spreadsheet using the IRiM accessory.
  • Ergonomic Design
    Whether you're using the MD 100 out in the field or in the lab, the design of the instrument  makes it easy to handle and view the display.
    If you're using the instrument in the lab, the rubber feet on the bottom of the housing eliminates the need for two hand operation or to chase your instrument around the workbench.
  • Factory Programmed
    All MD 100 instruments are supplied ready to use with up to 14 calibration curves.
    All you need to do is select the test you need, prepare your sample and test!
  • Scroll Driven Menu System
    The simple interface allows you to quickly reach the test you need.
    When the instrument is turned on, it will automatically display the last test used.
  • 2-Year Warranty
Optics LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used. Wavelength specifications of interference filters:
430 nm Δλ = 5 nm
530 nm Δλ = 5 nm
560 nm Δλ = 5 nm
580 nm Δλ = 5 nm
610 nm Δλ = 6 nm
660 nm Δλ = 5 nm
Wavelength Accuracy ± 1
Photometric Range -2500 - 2500 mAbs
Photometric Accuracy 3 % FS (T = 20 °C – 25 °C)
Suitable Vials Round Cuvettes 24 mm
Display backlit LCD (on keypress)
Interfaces Infrared
Operation Foil keypad
Auto – OFF Yes
Calibration factory calibration and user calibration. Reset to factory calibration possible
Internal Storage internal ring memory for 16 data sets
Power Supply 4 micro batteries (AAA)
Battery Life Time approx. 17 hours
Clock Real Time Clock and Date
Portability Portable
Environmental Conditions Temperature:  5 - 40 °C rel. humidity: 30 - 90 % (non condensing)
Protection Class IP 68
Compliance CE
Dimensions 155 x 75 x 35 mm
Weight 260 g
Testparameter Measuring Range Method No. Chemical Method
Aluminium PP 0.01 - 0.25 mg/L Al M50 Eriochrom Cyanine R

Chloride L (B)

0.5 - 20 mg/L Cl- M92 Mercury Thiocyanate / Iron Nitrate
Copper T 0.05 - 5 mg/L Cu M150 Biquinoline
DEHA PP 0.02 - 0.5 mg/L DEHA M167 PPST
Hydrazine P 0.05 - 0.5 mg/L N2H4 M205 Dimethylaminobenzaldehyde
Iron LR L (A) 0.03 - 2 mg/L Fe M225 Ferrozine / Thioglycolate
Oxygen dissolved C 10 - 800 µg/L O2 M292 Rhodazine D TM
Phosphate HR L 5 - 80 mg/L PO4 M335 Vanadomolybdate
Polyacrylate L 1 - 30 mg/L Polyacryl M338 Turbidity
Silicate HR PP 1 - 90 mg/L SiO2 M352 Silicomolybdate
Title Measuring Range Chemical Method Packaging Unit Part Number Add to quotation cart
VARIO Aluminium Reagent, Set F20 0.01 - 0.25 mg/L Al Eriochrom Cyanine R 1 pc. 535000
Chloride Reagent Set 0.5 - 20 mg/L Cl- Mercury Thiocyanate / Iron Nitrate 1 pc. 56R018490
Copper No. 1 0.05 - 5 mg/L Cua) Biquinoline Tablet / 100 513550BT
Copper No. 1 0.05 - 5 mg/L Cua) Biquinoline Tablet / 250 513551BT
Copper No. 2 0.05 - 5 mg/L Cua) Biquinoline Tablet / 100 513560BT
Copper No. 2 0.05 - 5 mg/L Cua) Biquinoline Tablet / 250 513561BT
Set Copper No. 1/No. 2 100 Pc. 0.05 - 5 mg/L Cua) Biquinoline 100 each 517691BT
Set Copper No. 1/No. 2 250 Pc. 0.05 - 5 mg/L Cua) Biquinoline 250 each 517692BT
VARIO DEHA Reagent Set 0.02 - 0.5 mg/L DEHA PPST 1 pc. 536000
Hydrazine Test Powder 0.05 - 0.5 mg/L N2H4 Dimethylaminobenzaldehyde Powder / 30 g 462910
Acidity / Alkalinity P Indicator PA1 0.03 - 2 mg/L Fe Ferrozine / Thioglycolate 65 mL 56L013565
Hardness Calcium Buffer CH2 0.03 - 2 mg/L Fe Ferrozine / Thioglycolate 65 mL 56L014465
KP962-Ammonium Persulphate Powder 0.03 - 2 mg/L Fe Ferrozine / Thioglycolate Powder / 40 g 56P096240
KS63-FE6-Thioglycolate/Molybdate HR RGT 0.03 - 2 mg/L Fe Ferrozine / Thioglycolate 30 mL 56L006330
Iron Reagent FE6 0.03 - 2 mg/L Fe Ferrozine / Thioglycolate 65 mL 56L006365
Iron Reagent FE5 0.03 - 2 mg/L Fe Ferrozine / Thioglycolate 65 mL 56L006165
Iron LR Reagent Set 0.03 - 2 mg/L Fe Ferrozine / Thioglycolate 1 pc. 56R018990
Vacu-vial Oxygen Test Kit 10 - 800 µg/L O2 c) Rhodazine D TM 1 Set 380450
KS278-Sulphuric Acid 50 % V/V 5 - 80 mg/L PO4 Vanadomolybdate 65 mL 56L027865
Phosphate HR, Ortho Reagent Set 5 - 80 mg/L PO4 Vanadomolybdate 1 pc. 56R019090
KS173-P2-2,4 Dinitrophenol Indicator 1 - 30 mg/L Polyacryl Turbidity 65 mL 56L017365
Polyacrylate L Reagent Set 1 - 30 mg/L Polyacryl Turbidity 1 pc. 56R019165
KS336-Propan-2-ol, 65 mL 1 - 30 mg/L Polyacryl Turbidity 65 mL 56L033665
VARIO Silica HR Reagent, Set F10 1 - 90 mg/L SiO2 Silicomolybdate 1 Set 535700
Title Online Download Type Format Language Direct Download
Datasheet 276230 - MD 100 Boiler Water Datasheet PDF (0.20 MB)
Instruction Manual MD 100, MD 110, MD 200 Instruction Manual PDF (12.01 MB)
Instruction Manual Single Method M150 - Copper T Procedure Single Method PDF (3.04 MB)
Instruction Manual Single Method M167 - DEHA PP Procedure Single Method PDF (4.04 MB)
Instruction Manual Single Method M205 - Hydrazine P Procedure Single Method PDF (2.52 MB)
Instruction Manual Single Method M225 - Iron LR L (A) Procedure Single Method PDF (4.48 MB)
Instruction Manual Single Method M292 - Oxygen dissolved C Procedure Single Method PDF (2.96 MB)
Instruction Manual Single Method M335 - Phosphate HR L Procedure Single Method PDF (3.98 MB)
Instruction Manual Single Method M338 - Polyacrylate L Procedure Single Method PDF (2.52 MB)
Instruction Manual Single Method M352 - Silicate HR PP Procedure Single Method PDF (2.56 MB)
Instruction Manual Single Method M50 - Aluminium PP Procedure Single Method PDF (4.02 MB)
Instruction Manual Single Method M92 - Chloride L (B) Procedure Single Method PDF (2.99 MB)
00386480 - MD1x0/200 - Chloride L (B), Aluminium PP, Copper T, DEHA PP, Hydrazine P, Iron LR L (A), Oxygen dissolved C, Phosphate HR L, Polyacrylate L, Silicate HR PP Handbook of Methods MD100/110/200 PDF (16.69 MB)
Declaration of Conformity md_100 Declaration of Conformity PDF (0.19 MB)
  • Instrument in plastic case
  • Adapter for ø 16 mm cuvettes
  • Adapter for ø 13 mm cuvettes
  • 4 micro batteries (AAA)
  • 3 round cuvettes (glass) with lid
  • 3 round cuvettes ø 16 mm (glass) with lid
  • Sealing rings
  • Stirring rod
  • Brush
  • Syringe (20 ml)
  • Measuring Beaker (100 ml)
  • Plastic centrifuge tubes
  • Instruction manual
  • Quick Start Guide
  • Certificate (COC)
  • Warranty information
Title SDS Country Direct Download
Acidity / Alkalinity P Indicator PA1
Copper No_1
Copper No_2
Copper No_2 (valid until Lot U0KA)
Hardness Calcium Buffer CH2
Hydrazine Test Powder
Iron Reagent FE5
Iron Reagent FE6
KP962 - Ammonium Persulphate Powder
KS173 - P2 - 2_4 Dinitrophenol Indicator
KS228 - Ammonium Molybdate PB1 Phosphate
KS229 - Ammonium Metavanadate PB2 Phosphate
KS278 - HFE1- PN1 - Sulphuric Acid 50pc v/v
KS336 - Propan-2-ol_Iso-Propyl Alcohol
Polyacrylate Buffer A1
Polyacrylate Precipitant A2
Vario Aluminum ECR F20
Vario DEHA 2 RGT
Vario ECR-Masking RGT
Vario Hexamine F20
Vario Oxyscav 1 RGT
Vario Silica Citric Acid F10_F25
Vario Silica HR Acid RGT F10_F25_Batch_U03A
Vario Silica HR Molybdate F10_F25