MD 110 COD

Photometer with Bluetooth® Technology

  • Bluetooth® -Interface
  • Scroll Memory
  • Automatic switch-off
  • Calibration mode indicator

Bluetooth® function

All MD 110 photometers have a Bluetooth® function. To make the most of it, Tintometer offers an app for mobile devices as well as a PC software with dongle. The measurement results are transmitted to external devices via the Bluetooth® interface for quick evaluation and processing so that all data can be evaluated and assigned directly on site.

App AquaLX®

The free app AquaLX® is ideally designed for use in on-site measurements. Compatible with IOS®- and Android®-based smartphones and tablets, it enables uncomplicated data transmission. It maps all measured values ​​as an illustrative graphic with minimum and maximum limits and supports the export of the data as an Excel®-compatible CSV file.

PC Software

The PC software makes it possible to import data directly from the photometer to the Windows-based PC. As a stationary solution, it facilitates the transfer of data through a quickly established, permanently wireless connection. Further processing of the results can be done both in the software itself and by exporting the data to Excel or as a CSV file.
The set of software and Bluetooth® dongle is available as a separate accessory under item no. 2444480 available.

Note according to EU regulation 2019/1148
Acquisition, introduction, possession or use of this product by the general public is restricted by Regulation (EU) 2019/1148. All suspicious transactions, and significant disappearances and thefts should be reported to the relevant national contact point. See https://ec.europa.eu/info/index_en

 

Part Number 2961202

1 pc.

Add to quotation cart

Applications

  • Raw Water Treatment
  • Waste Water Treatment

Product information

The MD 110 has several key features that make it a favorite among users.

  • Waterproof Design
    The IP 68 design of this instrument ensures that the MD 110 remains water tight for up to 1 hour at 0.1 meter.  Don't worry about dropping the instrument into a body of water - it floats!
  • Accurate, Reproducible Results
    The optical system of the MD 110 utilizes LEDs and interference filters which quickly gives you results that you can be confident in.
  • User Calibration Mode
    A one-point calibration is possible.  Additionally, all MD 110 instruments have the ability to display readings directly in ABS or %T units.
  • One-time-Zero Function
    Don't waste time waiting for your instrument to Zero after each test.  When testing a new sample, zero the instrument once and all subsequent tests of that sample do not require you to re-zero the instrument.
  • Automatic Data Storage with Transfer Capabilities
    The MD 110 automatically stores the last 16 readings with time and date stamp.  These results can be transferred to a spreadsheet using the IRiM accessory.
  • Ergonomic Design
    Whether you're using the MD 110 out in the field or in the lab, the design of the instrument  makes it easy to handle and view the display.   If you're using the instrument in the lab, the rubber feet on the bottom of the housing eliminates the need for two hand operation or to chase your instrument around the workbench.
  • Factory Programmed
    All MD 110 instruments are supplied ready to use with up to 14 calibration curves.  All you need to do is select the test you need, prepare your sample and test!
  • Scroll Driven Menu System
    The simple interface allows you to quickly reach the test you need.  When the instrument is turned on, it will automatically display the last test used.
  • 2-Year Warranty
Optics LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used. Wavelength specifications of interference filters:
430 nm Δλ = 5 nm
530 nm Δλ = 5 nm
560 nm Δλ = 5 nm
580 nm Δλ = 5 nm
610 nm Δλ = 6 nm
660 nm Δλ = 5 nm
Wavelength Accuracy ± 1
Photometric Range -2500 - 2500 mAbs
Photometric Accuracy 3 % FS (T = 20 °C – 25 °C)
Display backlit LCD (on keypress)
Interfaces Bluetooth
Operation Foil keypad
Auto – OFF Yes
Calibration factory calibration and user calibration. Reset to factory calibration possible
Internal Storage internal ring memory for 125 data sets
Power Supply 4 micro batteries (AAA)
Battery Life Time approx. 17 hours
Clock Real Time Clock and Date
Portability Portable
Degree of Pollution 2
Maximum altitude above sea level 2000 m
Environmental Conditions temperature:  5 - 40 °C rel. humidity: 30 - 90 % (non condensing)
Protection Class IP 68
Compliance CE
Dimensions 155 x 75 x 35 mm
Weight 260 g
Testparameter Measuring Range Method No. Chemical Method
COD HR TT 200 - 15000 mg/L COD M132 Dichromate / H2SO4
COD LMR TT 15 - 300 mg/L COD M133 Dichromate / H2SO4
COD LR TT 3 - 150 mg/L COD M130 Dichromate / H2SO4
COD MR TT 20 - 1500 mg/L COD M131 Dichromate / H2SO4
Title Measuring Range Chemical Method Packaging Unit Part Number Add to quotation cart
COD LR/25 3 - 150 mg/L CODb) Dichromate / H2SO4 25 pc. 2420720
COD LR/25, mercury free 3 - 150 mg/L CODb) Dichromate / H2SO4 25 pc. 2420710
COD LR/150 3 - 150 mg/L CODb) Dichromate / H2SO4 150 pc. 2420725
COD MR/25 20 - 1500 mg/L CODb) Dichromate / H2SO4 25 pc. 2420721
COD MR/25, mercury free 20 - 1500 mg/L CODb) Dichromate / H2SO4 25 pc. 2420711
COD MR/150 20 - 1500 mg/L CODb) Dichromate / H2SO4 150 pc. 2420726
COD MR/150, mercury free 20 - 1500 mg/L CODb) Dichromate / H2SO4 150 pc. 2420716
COD HR/25 200 - 15000 mg/L CODb) Dichromate / H2SO4 25 pc. 2420722
COD HR/25, mercury free 200 - 15000 mg/L CODb) Dichromate / H2SO4 25 pc. 2420712
COD HR/150 200 - 15000 mg/L CODb) Dichromate / H2SO4 150 pc. 2420727
COD LMR/25 15 - 300 mg/L CODb) Dichromate / H2SO4 25 pc. 2423120
Title Online Download Type Format Language Direct Download
Datasheet 2961202 - MD 110 COD Datasheet PDF (0.20 MB)
Instruction Manual MD 100, MD 110, MD 200 Instruction Manual PDF (12.01 MB)
Instruction Manual Single Method M130 - COD LR TT Procedure Single Method PDF (4.10 MB)
Instruction Manual Single Method M131 - COD MR TT Procedure Single Method PDF (3.50 MB)
Instruction Manual Single Method M132 - COD HR TT Procedure Single Method PDF (3.51 MB)
Instruction Manual Single Method M133 - COD LMR TT Procedure Single Method PDF (3.51 MB)
00386448 - MD1x0/200 - COD HR TT, COD LMR TT, COD LR TT, COD MR TT Handbook of Methods MD100/110/200 PDF (6.30 MB)
Information Bluetooth® Information Bluetooth PDF (0.02 MB)
EU-Declaration of Conformity MD 110 Declaration of Conformity PDF (0.13 MB)
Validation Data COD High Range Validation Data PDF (0.12 MB)
Validation Data COD High Range, Mercury free Validation Data PDF (0.06 MB)
Validation Data COD Low Range Validation Data PDF (0.12 MB)
Validation Data COD Low Range, Mercury free Validation Data PDF (0.06 MB)
Validation Data COD Mid Range Validation Data PDF (0.11 MB)
Validation Data COD Mid Range, Mercury free Validation Data PDF (0.06 MB)
  • Instrument in plastic case
  • Adapter for ø 16 mm cuvettes
  • 4 micro batteries (AAA)
  • Syringe (1 ml)
  • Syringe (2 ml)
  • Instruction manual
  • Quick Start Guide
  • Certificate (COC)
  • Warranty information
Title SDS Country Direct Download
COD CSB 15-300 mg l
COD _ CSB 0-150 mgL
COD _ CSB 0-1500 mgL
COD _ CSB 0-15000 mgL
COD_CSB Mercury Free 0-150 mgL
COD_CSB Mercury Free 0-1500 mgL
COD_CSB Mercury Free 0-15000 mgL
The Bluetooth®  word mark is a registered trademark owned by Bluetooth SIG, Inc. and any use by Lovibond® Tintometer GmbH is under license. IOS® is a registered trademark of Cisco, Inc. and licensed to Apple, Inc. Android™ is a trademark of Google, Inc.
Bluetooth®  is a wireless technology subject to regional approval. The use of Lovibond® instruments with Bluetooth® technology is currently only allowed in certain regions of the world. The use of the instruments will also be possible in other regions in the future. For current regions and further information, click here