In order to give you a better service Tintometer uses cookies. By continuing to browse the site you are agreeing to our use of cookies.

MD 110 Chlorine, pH, Cyanuric acid, tablet reagents

Photometer with Bluetooth® Technology

Mark as favourite

Part Number 2980102

Highlights

  • Bluetooth® -Interface
  • Scroll Memory
  • Automatic switch-off
  • Calibration mode indicator

Bluetooth® function

All MD 110 photometers have a Bluetooth® function. To make the most of it, Tintometer offers an app for mobile devices as well as a PC software with dongle.
The measurement results are transmitted to external devices via the Bluetooth® interface for quick evaluation and processing so that all data can be evaluated and assigned directly on site.

App AquaLX®

The free app AquaLX® is ideally designed for use in on-site measurements. Compatible with IOS®- and Android®-based smartphones and tablets, it enables uncomplicated data transmission. It maps all measured values ​​as an illustrative graphic with minimum and maximum limits and supports the export of the data as an Excel®-compatible CSV file.

The PC software makes it possible to import data directly from the photometer to the Windows-based PC using the included Bluetooth® dongle. As a stationary solution, it facilitates the transfer of data through a quickly established, permanently wireless connection. Further processing of the results can be done both in the software itself and by exporting the data to Excel or as a CSV file.
The set of software and Bluetooth® dongle is available as a separate accessory under item no. 2444480 available.

Applications

  • Boiler Water
  • Cooling Water
  • Disinfection Control
  • Drinking Water Treatment
  • Pool Water Control
  • Pool Water Treatment
  • Raw Water Treatment
  • Waste Water Treatment

The MD 110 has several key features that make it a favorite among users.

  • Waterproof Design
    The IP 68 design of this instrument ensures that the MD 110 remains water tight for up to 1 hour at 0.1 meter.  Don't worry about dropping the instrument into a body of water - it floats!
  • Accurate, Reproducible Results
    The optical system of the MD 110 utilizes LEDs and interference filters which quickly gives you results that you can be confident in.
  • User Calibration Mode
    A one-point calibration is possible.  Additionally, all MD 110 instruments have the ability to display readings directly in ABS or %T units.
  • One-time-Zero Function
    Don't waste time waiting for your instrument to Zero after each test.  When testing a new sample, zero the instrument once and all subsequent tests of that sample do not require you to re-zero the instrument.
  • Automatic Data Storage with Transfer Capabilities
    The MD 110 automatically stores the last 16 readings with time and date stamp.  These results can be transferred to a spreadsheet using the IRiM accessory.
  • Ergonomic Design
    Whether you're using the MD 110 out in the field or in the lab, the design of the instrument  makes it easy to handle and view the display.   If you're using the instrument in the lab, the rubber feet on the bottom of the housing eliminates the need for two hand operation or to chase your instrument around the workbench.
  • Factory Programmed
    All MD 110 instruments are supplied ready to use with up to 14 calibration curves.  All you need to do is select the test you need, prepare your sample and test!
  • Scroll Driven Menu System
    The simple interface allows you to quickly reach the test you need.  When the instrument is turned on, it will automatically display the last test used.
  • 2-Year Warranty
Light Source LED
Optics LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used. Wavelength specifications of interference filters:
430 nm Δλ = 5 nm
530 nm Δλ = 5 nm
560 nm Δλ = 5 nm
580 nm Δλ = 5 nm
610 nm Δλ = 6 nm
660 nm Δλ = 5 nm
Wavelength Accuracy ± 1
Photometric Accuracy 3 % FS (T = 20 °C – 25 °C)
Operation Foil keypad
Display backlit LCD (on keypress)
Suitable Vials Round Cuvettes 24 mm
Calibration factory calibration and user calibration. Reset to factory calibration possible
Interfaces Bluetooth
Internal Storage internal ring memory for 125 data sets
Power Supply 4 micro batteries (AAA)
Battery Life Time approx. 17 hours
Auto – OFF Yes
Clock Real Time Clock and Date
Portability Portable
Environmental Conditions temperature:  5 - 40 °C rel. humidity: 30 - 90 % (non condensing)
Compliance CE
Protection Class IP 68
Dimensions 155 x 75 x 35 mm
Weight 260 g
Title Measuring Range Chemical Method Packaging Unit Part Number Mark as favourite
DPD No. 1 0.01 - 6.0 mg/l Cl2 a) DPD Tablet / 100 511050BT
DPD No. 1 0.01 - 6.0 mg/l Cl2 a) DPD Tablet / 250 511051BT
DPD No. 1 0.01 - 6.0 mg/l Cl2 a) DPD Tablet / 500 511052BT
DPD No. 3 0.01 - 6.0 mg/l Cl2 a) DPD Tablet / 100 511080BT
DPD No. 3 0.01 - 6.0 mg/l Cl2 a) DPD Tablet / 250 511081BT
DPD No. 3 0.01 - 6.0 mg/l Cl2 a) DPD Tablet / 500 511082BT
DPD No. 1 High Calcium 0.01 - 6.0 mg/l Cl2 a) DPD Tablet / 100 515740BT
DPD No. 1 High Calcium 0.01 - 6.0 mg/l Cl2 a) DPD Tablet / 250 515741BT
DPD No. 1 High Calcium 0.01 - 6.0 mg/l Cl2 a) DPD Tablet / 500 515742BT
DPD No. 3 High Calcium 0.01 - 6.0 mg/l Cl2 a) DPD Tablet / 100 515730BT
DPD No. 3 High Calcium 0.01 - 6.0 mg/l Cl2 a) DPD Tablet / 250 515731BT
DPD No. 3 High Calcium 0.01 - 6.0 mg/l Cl2 a) DPD Tablet / 500 515732BT
DPD No. 4 0.01 - 6.0 mg/l Cl2 a) DPD Tablet / 100 511220BT
DPD No. 4 0.01 - 6.0 mg/l Cl2 a) DPD Tablet / 250 511221BT
DPD No. 4 0.01 - 6.0 mg/l Cl2 a) DPD Tablet / 500 511222BT
DPD No. 1 HR 0.1 - 10 mg/l Cl2 a) DPD Tablet / 100 511500BT
DPD No. 1 HR 0.1 - 10 mg/l Cl2 a) DPD Tablet / 250 511501BT
DPD No. 1 HR 0.1 - 10 mg/l Cl2 a) DPD Tablet / 500 511502BT
DPD No. 3 HR 0.1 - 10 mg/l Cl2 a) DPD Tablet / 100 511590BT
DPD No. 3 HR 0.1 - 10 mg/l Cl2 a) DPD Tablet / 250 511591BT
DPD No. 3 HR 0.1 - 10 mg/l Cl2 a) DPD Tablet / 500 511592BT
Set DPD No. 1 HR/No. 3 HR 100 Pc. 0.1 - 10 mg/l Cl2 a) DPD 100 each 517791BT
Set DPD No. 1 HR/No. 3 HR 250 Pc. 0.1 - 10 mg/l Cl2 a) DPD 250 each 517792BT
CyA-Test 10 - 160 mg/l CyA Melamine Tablet / 100 511370BT
CyA-Test 10 - 160 mg/l CyA Melamine Tablet / 250 511371BT
Deionised Water 10 - 160 mg/l CyA Melamine 100 ml 461275
Deionised Water 10 - 160 mg/l CyA Melamine 250 ml 457022
Phenol Red Photometer 6.5 - 8.4 Phenol Red Tablet / 100 511770BT
Phenol Red Photometer 6.5 - 8.4 Phenol Red Tablet / 250 511771BT
Phenol Red Photometer 6.5 - 8.4 Phenol Red Tablet / 500 511772BT
Title Part Number Mark as favourite
Micro batteries (AAA), set of 4 1950026
Measuring beaker, 100 ml 384801
Stirring rod, 13 cm length 364100
Stirring rod, 13 cm length, set of 10 364120
Stirring rod, 10 cm length 364109
Stirring rod, 10 cm length, set of 10 364130
Mixing cylinder, 25 ml 19802650
Membrane filter set for use when preparing samples, 25 membrane filters 0.45 µm, 2 syringes 20 ml 366150
Plastic funnel with handle (white) 471007
Brush, 11 cm length 380230
Water sampler, AF 631 170500
500 ml bottle, AF 631 375069
Lid, AF 631 375068
Round cuvette 24 mm, set of 12 197620
Round cuvette 24 mm, set of 5 197629
Round cuvette 16 mm, set of 10 197665
Multy cuvette-2, set of 12 197600
Cuvette stand for 6 round cuvettes Ø 24 mm 418951
Cuvette stand for 10 round cuvettes Ø 16 mm 418957
Adapter for round cuvettes 16 mm 19802190
Cleaning cloth 197635
Sealing ring for round vials 24 mm, set of 12 197626
Kit of BT data transfer software and Bluetooth dobgle 2444480
Reference Standard Kit Chlorine - 0.2 and 1.0 275650
Reference Standard Kit Chlorine - 0.5 and 2.0 275655
Reference Standard Kit Chlorine - 1.0 and 4.0 275656
Reference Standard Kit pH - 7.45 275670
Verification Standard Kit MD 100 / 200 215670
Basic price for calibration certificate for each unit 999845
Additionally for each method 999855
Title Online Download Type Format Language Direct Download
Datasheet 2980102 - MD 110 Chlorine, pH, Cyanuric acid, tablet reagents Datasheet PDF (0.20 MB)
Instruction Manual Photometer-System MD 110 Cl, pH, CyA Instruction Manual PDF (5.40 MB)
Instruction Manual Single Method Chlorine HR T Instruction Manual PDF (2.14 MB)
Instruction Manual Single Method Chlorine T Instruction Manual PDF (2.15 MB)
Instruction Manual Single Method CyA T Instruction Manual PDF (1.11 MB)
Instruction Manual Single Method pH-value T Instruction Manual PDF (1.11 MB)
EU-Declaration of Conformity MD 110 Declaration of Conformity PDF (0.19 MB)
Validation Data DPD No.1 Free Chlorine Validation Data PDF (0.12 MB)
  • Instrument in plastic case with 4 micro batteries (AAA)
  • 3 Round vials (glass) with lid and sealing rings
  • 1 Stirring rod
  • 1 Brush
  • Tablet reagents and/or liquid reagents or VARIO Powder reagent
  • Instruction manual
  • Certificate (COC)
  • Warranty information
Title Part Number SDS Country Direct Download
CyA-Test 00511371
DPD No_1 00511051
DPD No_1 HR 00511501
DPD No_1 High Calcium 00515741
DPD No_3 00511081
DPD No_3 HR 00511591
DPD No_3 High Calcium 00515731
DPD No_4 00511221
Phenol red Photometer 00511771
The Bluetooth®  word mark is a registered trademark owned by Bluetooth SIG, Inc. and any use by Lovibond® Tintometer GmbH is under license. IOS® is a registered trademark of Cisco, Inc. and licensed to Apple, Inc. Android™ is a trademark of Google, Inc.
Bluetooth®  is a wireless technology subject to regional approval. The use of Lovibond® instruments with Bluetooth® technology is currently only allowed in certain regions of the world. The use of the instruments will also be possible in other regions in the future. For current regions and further information, click here