Part Number 2980102
All MD 110 photometers have a Bluetooth®
function. To make the most of it, Tintometer offers an app for mobile devices as well as a PC software with dongle.
The measurement results are transmitted to external devices via the Bluetooth®
interface for quick evaluation and processing so that all data can be evaluated and assigned directly on site.
The free app AquaLX® is ideally designed for use in on-site measurements. Compatible with IOS®- and Android®-based smartphones and tablets, it enables uncomplicated data transmission. It maps all measured values as an illustrative graphic with minimum and maximum limits and supports the export of the data as an Excel®-compatible CSV file.
The PC software makes it possible to import data directly from the photometer to the Windows-based PC. As a stationary solution, it facilitates the transfer of data through a quickly established, permanently wireless connection. Further processing of the results can be done both in the software itself and by exporting the data to Excel or as a CSV file.
The set of software and Bluetooth®
dongle is available as a separate accessory under item no. 2444480 available.
The MD 110 has several key features that make it a favorite among users.
Optics | LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used. Wavelength specifications of interference filters: 430 nm Δλ = 5 nm 530 nm Δλ = 5 nm 560 nm Δλ = 5 nm 580 nm Δλ = 5 nm 610 nm Δλ = 6 nm 660 nm Δλ = 5 nm |
Wavelength Accuracy | ± 1 |
Photometric Range | -2600 - 2600 mAbs |
Photometric Accuracy | 3 % FS (T = 20 °C – 25 °C) |
Operation | Foil keypad |
Display | backlit LCD (on keypress) |
Suitable Vials | Round Cuvettes 24 mm |
Calibration | factory calibration and user calibration. Reset to factory calibration possible |
Interfaces | Bluetooth |
Internal Storage | internal ring memory for 125 data sets |
Power Supply | 4 micro batteries (AAA) |
Battery Life Time | approx. 17 hours |
Auto – OFF | Yes |
Clock | Real Time Clock and Date |
Portability | Portable |
Environmental Conditions | temperature: 5 - 40 °C rel. humidity: 30 - 90 % (non condensing) |
Compliance | CE |
Protection Class | IP 68 |
Dimensions | 155 x 75 x 35 mm |
Weight | 260 g |
Testparameter | Measuring Range | Method No. | Chemical Method |
---|---|---|---|
Chlorine HR T | 0.1 - 10 mg/l Cl2 | M103 | DPD |
Chlorine T | 0.01 - 6.0 mg/l Cl2 | M100 | DPD |
CyA T | 10 - 160 mg/l CyA | M160 | Melamine |
pH-value T | 6.5 - 8.4 | M330 | Phenol Red |
Title | Measuring Range | Chemical Method | Packaging Unit | Part Number | Mark as favourite |
---|---|---|---|---|---|
DPD No. 1 | 0.01 - 6.0 mg/l Cl2 a) | DPD | Tablet / 100 | 511050BT |
|
DPD No. 1 | 0.01 - 6.0 mg/l Cl2 a) | DPD | Tablet / 250 | 511051BT |
|
DPD No. 1 | 0.01 - 6.0 mg/l Cl2 a) | DPD | Tablet / 500 | 511052BT |
|
DPD No. 3 | 0.01 - 6.0 mg/l Cl2 a) | DPD | Tablet / 100 | 511080BT |
|
DPD No. 3 | 0.01 - 6.0 mg/l Cl2 a) | DPD | Tablet / 250 | 511081BT |
|
DPD No. 3 | 0.01 - 6.0 mg/l Cl2 a) | DPD | Tablet / 500 | 511082BT |
|
DPD No. 1 High Calcium | 0.01 - 6.0 mg/l Cl2 a) | DPD | Tablet / 100 | 515740BT |
|
DPD No. 1 High Calcium | 0.01 - 6.0 mg/l Cl2 a) | DPD | Tablet / 250 | 515741BT |
|
DPD No. 1 High Calcium | 0.01 - 6.0 mg/l Cl2 a) | DPD | Tablet / 500 | 515742BT |
|
DPD No. 3 High Calcium | 0.01 - 6.0 mg/l Cl2 a) | DPD | Tablet / 100 | 515730BT |
|
DPD No. 3 High Calcium | 0.01 - 6.0 mg/l Cl2 a) | DPD | Tablet / 250 | 515731BT |
|
DPD No. 3 High Calcium | 0.01 - 6.0 mg/l Cl2 a) | DPD | Tablet / 500 | 515732BT |
|
DPD No. 4 | 0.01 - 6.0 mg/l Cl2 a) | DPD | Tablet / 100 | 511220BT |
|
DPD No. 4 | 0.01 - 6.0 mg/l Cl2 a) | DPD | Tablet / 250 | 511221BT |
|
DPD No. 4 | 0.01 - 6.0 mg/l Cl2 a) | DPD | Tablet / 500 | 511222BT |
|
DPD No. 1 HR | 0.1 - 10 mg/l Cl2 a) | DPD | Tablet / 100 | 511500BT |
|
DPD No. 1 HR | 0.1 - 10 mg/l Cl2 a) | DPD | Tablet / 250 | 511501BT |
|
DPD No. 1 HR | 0.1 - 10 mg/l Cl2 a) | DPD | Tablet / 500 | 511502BT |
|
DPD No. 3 HR | 0.1 - 10 mg/l Cl2 a) | DPD | Tablet / 100 | 511590BT |
|
DPD No. 3 HR | 0.1 - 10 mg/l Cl2 a) | DPD | Tablet / 250 | 511591BT |
|
DPD No. 3 HR | 0.1 - 10 mg/l Cl2 a) | DPD | Tablet / 500 | 511592BT |
|
Set DPD No. 1 HR/No. 3 HR 100 Pc. | 0.1 - 10 mg/l Cl2 a) | DPD | 100 each | 517791BT |
|
Set DPD No. 1 HR/No. 3 HR 250 Pc. | 0.1 - 10 mg/l Cl2 a) | DPD | 250 each | 517792BT |
|
CyA-Test | 10 - 160 mg/l CyA | Melamine | Tablet / 100 | 511370BT |
|
CyA-Test | 10 - 160 mg/l CyA | Melamine | Tablet / 250 | 511371BT |
|
Deionised Water | 10 - 160 mg/l CyA | Melamine | 100 ml | 461275 |
|
Deionised Water | 10 - 160 mg/l CyA | Melamine | 250 ml | 457022 |
|
Phenol Red Photometer | 6.5 - 8.4 | Phenol Red | Tablet / 100 | 511770BT |
|
Phenol Red Photometer | 6.5 - 8.4 | Phenol Red | Tablet / 250 | 511771BT |
|
Phenol Red Photometer | 6.5 - 8.4 | Phenol Red | Tablet / 500 | 511772BT |
|