MD 200 Ozone, tablet reagents

Precise results using high-quality interference filters

  • Scroll memory
  • Automatic switch-off
  • Real-Time-Clock and date
  • Calibration mode indicator
Versatile, compact and: The benchtop photometer MD 200 combines high-quality interference filters with long-term stable LEDs as light sources in a high-precision optic. The result: precise measurement results at all times - no matter where you use it.

 

Part Number 2899802

1 pc.

Add to quotation cart

Applications

  • Boiler Water
  • Disinfection Control
  • Drinking Water Treatment
  • Raw Water Treatment
  • Waste Water Treatment

Product information

  • Versatile use
    The MD 200 photometer can be used in almost all areas of water analysis.
  • Precise and low maintenance
    The high-precision optics, which in addition to long-term stable LEDs as light sources, also offer high-quality interference filters, ensure precise and reproducible measurement results. In addition, these components make the photometer low-maintenance.
  • User friendly
    The devices impress with their ease of use, ergonomic design and compact dimensions, which makes handling the devices easy and safe.
  • Reagents
    Use long-term stable Lovibond® reagent tablets (5-10 years guaranteed minimum durability) or Lovibond® liquid reagents.
Optics LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending
on the version, up to 3 different interference filters are used. Wavelength specifications of
interference filters:
430 nm Δλ = 5 nm
530 nm Δλ = 5 nm
560 nm Δλ = 5 nm
610 nm Δλ = 6 nm
Wavelength Accuracy ± 1 nm
Photometric Range -2500 - 2500 mAbs
Photometric Accuracy 3 % FS (T = 20 °C – 25 °C)
Display backlit LCD (on keypress)
Interfaces Infrared
Operation Foil keypad
Auto – OFF Yes
Calibration Factory calibration and user calibration. Reset to factory calibration possible.
Internal Storage internal ring memory for 16 data sets
Power Supply 4 batteries (AA)
Battery Life Time approx. 53 hours
Clock Real Time Clock and Date
Portability Portable
Environmental Conditions temperature:  5 - 40 °C rel. humidity: 30 - 90 % (non condensing)
Protection Class IP 68
Compliance CE
Dimensions 110 x 55 x 190 mm
Weight 455 g
Testparameter Measuring Range Method No. Chemical Method
Ozone T 0.02 - 2 mg/L O3 M300 DPD / Glycine
Title Measuring Range Chemical Method Packaging Unit Part Number Add to quotation cart
DPD No.1 0.02 - 2 mg/L O3 DPD / Glycine Tablet / 100 511050BT
DPD No. 1 0.02 - 2 mg/L O3 DPD / Glycine Tablet / 250 511051BT
DPD No. 1 0.02 - 2 mg/L O3 DPD / Glycine Tablet / 500 511052BT
DPD No. 3 0.02 - 2 mg/L O3 DPD / Glycine Tablet / 100 511080BT
DPD No. 3 0.02 - 2 mg/L O3 DPD / Glycine Tablet / 250 511081BT
DPD No. 3 0.02 - 2 mg/L O3 DPD / Glycine Tablet / 500 511082BT
DPD No. 1 High Calcium 0.02 - 2 mg/L O3 DPD / Glycine Tablet / 100 515740BT
DPD No. 1 High Calcium 0.02 - 2 mg/L O3 DPD / Glycine Tablet / 250 515741BT
DPD No. 1 High Calcium 0.02 - 2 mg/L O3 DPD / Glycine Tablet / 500 515742BT
DPD No. 3 High Calcium 0.02 - 2 mg/L O3 DPD / Glycine Tablet / 100 515730BT
DPD No. 3 High Calcium 0.02 - 2 mg/L O3 DPD / Glycine Tablet / 250 515731BT
DPD No. 3 High Calcium 0.02 - 2 mg/L O3 DPD / Glycine Tablet / 500 515732BT
Glycine 0.02 - 2 mg/L O3 DPD / Glycine Tablet / 100 512170BT
Glycine 0.02 - 2 mg/L O3 DPD / Glycine Tablet / 250 512171BT
Set DPD No. 1/No. 3 100 Pc. 0.02 - 2 mg/L O3 DPD / Glycine 100 each 517711BT
Set DPD No. 1/No. 3 250 Pc. 0.02 - 2 mg/L O3 DPD / Glycine 250 each 517712BT
Set DPD No. 1/No. 3 High Calcium 100 Pc. 0.02 - 2 mg/L O3 DPD / Glycine 100 each 517781BT
Set DPD No. 1/No. 3 High Calcium 250 Pc. 0.02 - 2 mg/L O3 DPD / Glycine 250 each 517782BT
Set DPD No. 1/Glycine 100 Stck. 0.02 - 2 mg/L O3 DPD / Glycine 100 each 517731BT
Set DPD No. 1/Glycine 250 Stck. 0.02 - 2 mg/L O3 DPD / Glycine 250 each 517732BT
Title Online Download Type Format Language Direct Download
Datasheet 2899802 - MD 200 Ozone, tablet reagents Datasheet PDF (0.20 MB)
Instruction Manual MD 100, MD 110, MD 200 Instruction Manual PDF (12.01 MB)
Instruction Manual Single Method M300 - Ozone T Procedure Single Method PDF (4.46 MB)
00386460 - MD1x0/200 - Ozone T Handbook of Methods MD100/110/200 PDF (6.36 MB)
Declaration of Conformity md_200 Declaration of Conformity PDF (0.12 MB)
Validation Data DPD No.1 Free Chlorine Validation Data PDF (0.12 MB)
  • Instrument in plastic case with 4 batteries (AA)
  • 3 Round vials with lids
  • Sealing rings
  • 1 Stirring rod
  • 1 Brush
  • 1 Syringe (depending on version)
  • 100 tablet reagents DPD No. 1
  • 100 tablet reagents DPD No. 3 Evo
  • 100 tablet reagents Glycine
  • Instruction manual
  • Manual of Methods
  • Certificate (COC)
  • Warranty information
Title SDS Country Direct Download
DPD No. 1
DPD No. 1 High Calcium
DPD No. 3 High Calcium
DPD No. 3 from Lot Code YA1E0132
Glycine