MD 110 Boiler Water

Photometer with Bluetooth® Technology

  • Bluetooth® -Interface
  • Scroll Memory
  • Automatic switch-off
  • Calibration mode indicator

Bluetooth® function

All MD 110 photometers have a Bluetooth® function. To make the most of it, Tintometer offers an app for mobile devices as well as a PC software with dongle.
The measurement results are transmitted to external devices via the Bluetooth® interface for quick evaluation and processing so that all data can be evaluated and assigned directly on site.

App AquaLX®

The free app AquaLX® is ideally designed for use in on-site measurements. Compatible with IOS®- and Android®-based smartphones and tablets, it enables uncomplicated data transmission. It maps all measured values ​​as an illustrative graphic with minimum and maximum limits and supports the export of the data as an Excel®-compatible CSV file.

The PC software makes it possible to import data directly from the photometer to the Windows-based PC using the included Bluetooth® dongle. As a stationary solution, it facilitates the transfer of data through a quickly established, permanently wireless connection. Further processing of the results can be done both in the software itself and by exporting the data to Excel or as a CSV file.
The set of software and Bluetooth® dongle is available as a separate accessory under item no. 2444480 available.

 

Part Number 2962302

1 pc.

Add to quotation cart

Applications

  • Boiler Water
  • Cooling Water
  • Drinking Water Treatment
  • Galvanization
  • Pool Water Control
  • Raw Water Treatment
  • Waste Water Treatment

Product information

The MD 110 has several key features that make it a favorite among users.

  • Waterproof Design
    The IP 68 design of this instrument ensures that the MD 110 remains water tight for up to 1 hour at 0.1 meter.  Don't worry about dropping the instrument into a body of water - it floats!
  • Accurate, Reproducible Results
    The optical system of the MD 110 utilizes LEDs and interference filters which quickly gives you results that you can be confident in.
  • User Calibration Mode
    A one-point calibration is possible.  Additionally, all MD 110 instruments have the ability to display readings directly in ABS or %T units.
  • One-time-Zero Function
    Don't waste time waiting for your instrument to Zero after each test.  When testing a new sample, zero the instrument once and all subsequent tests of that sample do not require you to re-zero the instrument.
  • Automatic Data Storage with Transfer Capabilities
    The MD 110 automatically stores the last 16 readings with time and date stamp.  These results can be transferred to a spreadsheet using the IRiM accessory.
  • Ergonomic Design
    Whether you're using the MD 110 out in the field or in the lab, the design of the instrument  makes it easy to handle and view the display.   If you're using the instrument in the lab, the rubber feet on the bottom of the housing eliminates the need for two hand operation or to chase your instrument around the workbench.
  • Factory Programmed
    All MD 110 instruments are supplied ready to use with up to 14 calibration curves.  All you need to do is select the test you need, prepare your sample and test!
  • Scroll Driven Menu System
    The simple interface allows you to quickly reach the test you need.  When the instrument is turned on, it will automatically display the last test used.
  • 2-Year Manufacturer's Warranty
Optics LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used. Wavelength specifications of interference filters:
430 nm Δλ = 5 nm
530 nm Δλ = 5 nm
560 nm Δλ = 5 nm
580 nm Δλ = 5 nm
610 nm Δλ = 6 nm
660 nm Δλ = 5 nm
Wavelength Accuracy ± 1
Photometric Range -2500 - 2500 mAbs
Display backlit LCD (on keypress)
Interfaces Bluetooth
Operation Foil keypad
Calibration factory calibration and user calibration. Reset to factory calibration possible
Internal Storage internal ring memory for 125 data sets
Power Supply 4 micro batteries (AAA)
Battery Life Time approx. 17 hours
Clock Real Time Clock and Date
Portability Portable
Degree of Pollution 2
Maximum altitude above sea level 2000 m
Compliance CE
Dimensions 6.1 x 2.95 x 1.38"
Testparameter Measuring Range Method No. Chemical Method
Aluminium PP 0.01 - 0.25 mg/L Al M50 Eriochrom Cyanine R

Chloride L (B)

0.5 - 20 mg/L Cl- M92 Mercury Thiocyanate / Iron Nitrate
Copper T 0.05 - 5 mg/L Cu M150 Biquinoline
DEHA PP 0.02 - 0.5 mg/L DEHA M167 PPST
Hydrazine P 0.05 - 0.5 mg/L N2H4 M205 Dimethylaminobenzaldehyde
Iron LR L (A) 0.03 - 2 mg/L Fe M225 Ferrozine / Thioglycolate
Oxygen dissolved C 10 - 800 µg/L O2 M292 Rhodazine D TM
Phosphate HR L 5 - 80 mg/L PO4 M335 Vanadomolybdate
Polyacrylate L 1 - 30 mg/L Polyacryl M338 Turbidity
Silicate HR PP 1 - 90 mg/L SiO2 M352 Silicomolybdate
Title Measuring Range Chemical Method Packaging Unit Part Number Add to quotation cart
VARIO Aluminium Reagent, Set F20 0.01 - 0.25 mg/L Al Eriochrom Cyanine R 1 pc. 535000
Chloride Reagent Set 0.5 - 20 mg/L Cl- Mercury Thiocyanate / Iron Nitrate 1 pc. 56R018490
Copper No.1 Tablet Reagents, 100 pack 0.05 - 5 mg/L Cua) Biquinoline Tablet / 100 513550BT
Copper No.1 Tablet Reagents, 250 pack 0.05 - 5 mg/L Cua) Biquinoline Tablet / 250 513551BT
Copper No.2 Tablet Reagents, 100 pack 0.05 - 5 mg/L Cua) Biquinoline Tablet / 100 513560BT
Copper No.2 Tablet Reagents, 250 pack 0.05 - 5 mg/L Cua) Biquinoline Tablet / 250 513561BT
Set Copper No. 1/No. 2 100 Pc. 0.05 - 5 mg/L Cua) Biquinoline 100 each 517691BT
Set Copper No. 1/No. 2 250 Pc. 0.05 - 5 mg/L Cua) Biquinoline 250 each 517692BT
VARIO DEHA Reagent Set 0.02 - 0.5 mg/L DEHA PPST 1 pc. 536000
Hydrazine Test Powder 0.05 - 0.5 mg/L N2H4 Dimethylaminobenzaldehyde Powder / 30 g 462910
Acidity / Alkalinity P Indicator PA1 0.03 - 2 mg/L Fe Ferrozine / Thioglycolate 65 mL 56L013565
Hardness Calcium Buffer CH2 0.03 - 2 mg/L Fe Ferrozine / Thioglycolate 65 mL 56L014465
KP962-Ammonium Persulphate Powder 0.03 - 2 mg/L Fe Ferrozine / Thioglycolate Powder / 40 g 56P096240
KS63-FE6-Thioglycolate/Molybdate HR RGT 0.03 - 2 mg/L Fe Ferrozine / Thioglycolate 30 mL 56L006330
Iron Reagent FE6 0.03 - 2 mg/L Fe Ferrozine / Thioglycolate 65 mL 56L006365
Iron Reagent FE5 0.03 - 2 mg/L Fe Ferrozine / Thioglycolate 65 mL 56L006165
Iron LR Reagent Set 0.03 - 2 mg/L Fe Ferrozine / Thioglycolate 1 pc. 56R018990
Vacu-vial Oxygen Test Kit 10 - 800 µg/L O2 c) Rhodazine D TM 1 Set 380450
KS278-Sulphuric Acid 50 % V/V 5 - 80 mg/L PO4 Vanadomolybdate 65 mL 56L027865
Phosphate HR, Ortho Reagent Set 5 - 80 mg/L PO4 Vanadomolybdate 1 pc. 56R019090
KS173-P2-2,4 Dinitrophenol Indicator 1 - 30 mg/L Polyacryl Turbidity 65 mL 56L017365
Polyacrylate L Reagent Set 1 - 30 mg/L Polyacryl Turbidity 1 pc. 56R019165
KS336-Propan-2-ol, 65 mL 1 - 30 mg/L Polyacryl Turbidity 65 mL 56L033665
Title Online Download Type Format Language Direct Download
Datasheet 2962302 - MD 110 Boiler Water Datasheet PDF (0.20 MB)
Instruction Manual Instruction Manual PDF (12.01 MB)
Instruction Manual Single Method M150 - Copper T Instruction Manual PDF (3.04 MB)
Instruction Manual Single Method M167 - DEHA PP Instruction Manual PDF (4.04 MB)
Instruction Manual Single Method M205 - Hydrazine P Instruction Manual PDF (2.52 MB)
Instruction Manual Single Method M225 - Iron LR L (A) Instruction Manual PDF (4.48 MB)
Instruction Manual Single Method M292 - Oxygen dissolved C Instruction Manual PDF (2.96 MB)
Instruction Manual Single Method M335 - Phosphate HR L Instruction Manual PDF (3.98 MB)
Instruction Manual Single Method M338 - Polyacrylate L Instruction Manual PDF (2.52 MB)
Instruction Manual Single Method M352 - Silicate HR PP Instruction Manual PDF (2.56 MB)
Instruction Manual Single Method M50 - Aluminium PP Instruction Manual PDF (4.02 MB)
Instruction Manual Single Method M92 - Chloride L (B) Instruction Manual PDF (2.99 MB)
00386480 - MD1x0/200 - Chloride L (B), Aluminium PP, Copper T, DEHA PP, Hydrazine P, Iron LR L (A), Oxygen dissolved C, Phosphate HR L, Polyacrylate L, Silicate HR PP Instruction Manual PDF (16.69 MB)
Information Bluetooth® Information Bluetooth PDF (0.02 MB)
EU-Declaration of Conformity Declaration of Conformity PDF (0.13 MB)
  • Instrument in plastic case with 4 micro batteries (AAA)
  • 1 Adapter for round cuvettes 13 mm
  • 1 Adapter for round cuvettes 16 mm
  • 3 round vials 24 mm (glass) with lid and sealing rings
  • 3 round vials 16 mm (glass) with lid and sealing rings
  • 1 stirring rod
  • 1 brush
  • 1 Syringe (20 ml)
  • 1 Plastic shaker tube, graduated 30 ml, with lid
  • 1 Plastic shaker tube, graduated 100 ml, with lid
  • Instruction manual
  • Manual of Methods
  • Certificate (COC)
  • Warranty information
  • without reagents
Title SDS Country Direct Download
Copper No_1
Copper No_2
Copper No_2 (valid until Lot U0KA)
Hardness Calcium Buffer CH2
Hydrazine Test Powder
KS173 - P2 - 2_4 Dinitrophenol Indicator
KS228 - Ammonium Molybdate PB1 Phosphate
KS229 - Ammonium Metavanadate PB2 Phosphate
KS278 - HFE1- PN1 - Sulphuric Acid 50pc v/v
KS336 - Propan-2-ol_Iso-Propyl Alcohol
Vario Aluminum ECR F20
Vario DEHA 2 RGT
Vario ECR-Masking RGT
Vario Hexamine F20
Vario Oxyscav 1 RGT
The Bluetooth®  word mark is a registered trademark owned by Bluetooth SIG, Inc. and any use by Lovibond® Tintometer GmbH is under license. IOS® is a registered trademark of Cisco, Inc. and licensed to Apple, Inc. Android™ is a trademark of Google, Inc.
Bluetooth®  is a wireless technology subject to regional approval. The use of Lovibond® instruments with Bluetooth® technology is currently only allowed in certain regions of the world. The use of the instruments will also be possible in other regions in the future. For current regions and further information, click here