MD 200 Hydrogen peroxide, pH, liquid reagents

Precise results using high-quality interference filters

  • Scroll memory
  • Automatic switch-off
  • Real-Time-Clock and date
  • Calibration mode indicator
Versatile, compact and: The benchtop photometer MD 200 combines high-quality interference filters with long-term stable LEDs as light sources in a high-precision optic. The result: precise measurement results at all times - no matter where you use it.

 

Part Number 2888102

1 pc.

Add to quotation cart

Applications

  • Boiler Water
  • Disinfection Control
  • Drinking Water Treatment
  • Pool Water Control
  • Raw Water Treatment
  • Waste Water Treatment

Product information

  • Versatile use
    The MD 200 photometer can be used in almost all areas of water analysis.
  • Precise and low maintenance
    The high-precision optics, which in addition to long-term stable LEDs as light sources, also offer high-quality interference filters, ensure precise and reproducible measurement results. In addition, these components make the photometer low-maintenance.
  • User friendly
    The devices impress with their ease of use, ergonomic design and compact dimensions, which makes handling the devices easy and safe.
  • Reagents
    Use long-term stable Lovibond® reagent tablets (5-10 years guaranteed minimum durability) or Lovibond® liquid reagents.
Optics LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending
on the version, up to 3 different interference filters are used. Wavelength specifications of
interference filters:
430 nm Δλ = 5 nm
530 nm Δλ = 5 nm
560 nm Δλ = 5 nm
610 nm Δλ = 6 nm
Wavelength Accuracy ± 1 nm
Photometric Range -2500 - 2500 mAbs
Photometric Accuracy 3 % FS (T = 20 °C – 25 °C)
Display backlit LCD (on keypress)
Interfaces Infrared
Operation Foil keypad
Auto – OFF Yes
Calibration Factory calibration and user calibration. Reset to factory calibration possible.
Internal Storage internal ring memory for 16 data sets
Power Supply 4 batteries (AA)
Battery Life Time approx. 53 hours
Clock Real Time Clock and Date
Portability Portable
Environmental Conditions temperature:  5 - 40 °C rel. humidity: 30 - 90 % (non condensing)
Protection Class IP 68
Compliance CE
Dimensions 110 x 55 x 190 mm
Weight 455 g
Testparameter Measuring Range Method No. Chemical Method
H2O2 HR L 40 - 500 mg/L H2O2 M214 Titanium Tetrachloride / Acid
H2O2 LR L 1 - 50 mg/L H2O2 M213 Titanium Tetrachloride / Acid
pH value L 6.5 - 8.4 pH M331 Phenol Red
Title Measuring Range Chemical Method Packaging Unit Part Number Add to quotation cart
Reagent for Hydrogen Peroxide 1 - 50 mg/L H2O2 Titanium Tetrachloride / Acid 15 mL 424991
Phenol Red Solution 6.5 - 8.4 pH Phenol Red 15 mL 471040
Phenol Red Solution 6.5 - 8.4 pH Phenol Red 100 mL 471041
Phenol Red Solution in 6-pack 6.5 - 8.4 pH Phenol Red 1 pc. 471046
Title Online Download Type Format Language Direct Download
Datasheet 2888102 - MD 200 Hydrogen peroxide, pH, liquid reagents Datasheet PDF (0.20 MB)
Instruction Manual MD 100, MD 110, MD 200 Instruction Manual PDF (12.01 MB)
Instruction Manual Single Method M213 - H2O2 LR L Procedure Single Method PDF (1.55 MB)
Instruction Manual Single Method M214 - H2O2 HR L Procedure Single Method PDF (1.56 MB)
Instruction Manual Single Method M331 - pH value L Procedure Single Method PDF (2.98 MB)
00386464 - MD1x0/200 - H2O2 HR L, H2O2 LR L, pH value L Handbook of Methods MD100/110/200 PDF (5.95 MB)
Declaration of Conformity md_200 Declaration of Conformity PDF (0.12 MB)
  • Instrument in plastic case with 4 batteries (AA)
  • 1 Adapter for round cuvettes 16 mm
  • 3 Round cuvette with lids, 24 mm
  • 3 Round cuvette with lid, 16 mm
  • Sealing rings
  • 1 Stirring rod
  • 1 Brush
  • 1 Syringe (10 ml)
  • Reagent for Hydrogen Peroxide
  • Phenol Red Solution
  • Instruction manual
  • Manual of Methods
  • Certificate (COC)
  • Warranty information
Title SDS Country Direct Download
H2O2 Reagent
Phenol red Solution