Mail: sales@lovibond.com
Tel.: +49 (0)231/94510-0
Closed water systems are closed to the greater environment and use very little Make Up (MU) water in their normal operation. A properly ‘tight’ system will have no more than 5 % MU water annually. Calcium based scale formation is not as significant a risk as corrosion is for these systems. The minimum recommended regular tests are:
Part Number 56K701120
The Closed Water Test Kit is designed for use on all types of closed water Systems such as chilled water circuits and heating systems.
The Kit should be used to monitor water conditions to ensure that the systems are under control and do not exhibit signs of corrosion, scaling or microbiological fouling.
The Closed Water Test Kit is supplied in its own robust carry case and includes all the equipment and reagents necessary to perform approx 100 tests.
Parámetros de prueba | Rango de medición | Número del método | Método químico |
---|---|---|---|
Conductivity | 0 - 20 mS/cm | SD / Con | |
Hierro LR T | 0.05 - 1 mg/L Fe | M2513 | PPST |
Molibdato HR T | 50 - 500 mg/L MoO4 | M2525 | Tioglicolato |
Nitrito |
10 - 2000 mg/L NaNO2 | 56I700300 | |
pH | 0 - 14 | SD / pH |
Título | Parámetro y rango | Parámetro del disco | Referencia No | Agregar al carrito de cotizaciones |
---|---|---|---|---|
Disco CHECKIT® hierro LR | Hierro LR T 0.05 - 1 mg/L Fe | 0,05 / 0,1 / 0,15 / 0,2 / 0,25 / 0,3 / 0,35 / 0,4 / 0,45 / 0,5 / 0,55 / 0,6 / 0,65 / 0,7 / 0,75 / 0,8 / 0,9 / 1,0 | 146220 | |
Disco CHECKIT® molibdato HR | Molibdato HR T 50 - 500 mg/L MoO4 | 50 / 100 / 150 / 200 / 250 / 300 / 500 | 146295 |
Título | Rango de medición | Método químico | Unidad de embalaje | Referencia No | Agregar al carrito de cotizaciones |
---|---|---|---|---|---|
Indicador de ferroína N1 | 10 - 2000 mg/L NaNO2 | 65 mL | 56L017165 |
|
|
Titulante para nitrito N2 | 10 - 2000 mg/L NaNO2 | 65 mL | 56L017265 |
|
|
Hierro II LR | 0.05 - 1 mg/L Fe | PPST | Tabletas / 100 | 515420BT |
|
Hierro II LR | 0.05 - 1 mg/L Fe | PPST | Tabletas / 250 | 515421BT |
|
Hierro LR | 0.05 - 1 mg/L Fe | PPST | Tabletas / 100 | 515370BT |
|
Hierro LR | 0.05 - 1 mg/L Fe | PPST | Tabletas / 250 | 515371BT |
|
Molibdato HR nº 1 | 50 - 500 mg/L MoO4 | Tioglicolato | Tabletas / 100 | 513060BT |
|
Molibdato HR nº 1 | 50 - 500 mg/L MoO4 | Tioglicolato | Tabletas / 250 | 513061BT |
|
Molibdato HR nº 2 | 50 - 500 mg/L MoO4 | Tioglicolato | Tabletas / 100 | 513070BT |
|
Molibdato HR nº 2 | 50 - 500 mg/L MoO4 | Tioglicolato | Tabletas / 250 | 513071BT |
|
Juego molibdato nº 1/nº 2 | 50 - 500 mg/L MoO4 | Tioglicolato | 100 cada | 517631BT |
|
Juego molibdato nº 1/nº 2 | 50 - 500 mg/L MoO4 | Tioglicolato | 250 cada | 517632BT |
|
Título | Referencia No | Agregar al carrito de cotizaciones |
---|---|---|
Jeringuilla, plástico, 20 mL | 56A006501 |
|
Tubo de ensayo 5/10 mL + tapa | 56A600401 |
|
Recipiente de valoración con tapa, plástico, 60 mL | 56A006701 |
|
Jeringuilla de plástico 1 ml | 56A013501 |
|
Comparator CHECKIT® | 145000 |
|
Varilla agitadora y cucharilla para polvo | 56A006601 |
|