Part Number 178109
This generation of online colorimeters measures a near real-time response across the spectrum (380 to 780 nm) or less. This spectrophotometric approach allows for the use of internationally recognised colour coordinate systems, such as CIELAB and CIE xzY with the subsequent translation of colour data to industry specific colour scales, as referenced by standardising bodies such as AOCS, DGF, ISO and ASTM.
Applicable Standard | AOCS Cc 8d-55 AOCS Cc 13a-43 AOCS Cc 13b-45 AOCS Cc 13e-92 AOCS Cc 13j-97 ASTM D1209 ASTM D1544 ASTM D6166 ASTM E308 BS684 ISO 6271 ISO 15305 |
Colour Type | Transparent |
Display | Embedded PC with touch screen display, internal hard drive Windows XP operatin system |
Path Length | 1 inch, 50 mm, 5 1/4 inch |
Calibration | Calibration loop filled with food grade glycerol, automatic calibration program included with software |
Internal Storage | 100,000+ Measurement |
Measurement Time | Less than 5 seconds (depending on length of fiber optic cable) |
Instrument Housing | Metal cabinet to IP66 |
Spectral Range | 320 - 780 nm |
Illuminants | CIE Illuminant A |
Portability | Process |
Observer | 2°, 10° |
Dimensions | 500 x 500 x 300 mm |
Weight | 24 kg |
Title | Scale Path Length | Scale Range | Scale Resolution | Applicable Standard | Mark as favourite |
---|---|---|---|---|---|
FAC Colour (AOCS Cc 13a-43) | 10.65 mm | 25 - 45 | 4 units | Array |
|
Gardner Colour (ASTM D 1544, ASTM D 6166, AOCS Td 1a, MS 817 Part 10) | 10 mm | 1 - 9 | 1 unit |
|
|
Gardner Colour (ASTM D 1544, ASTM D 6166, AOCS Td 1a, MS 817 Part 10) | 10 mm | 10 - 18 | 1 unit |
|
|
Lovibond® RYBN Colour | 10 mm - 5 1/4" | 0 - 70 R, 0 - 70 Y, 0 - 30 B, 0 - 3 N | 0.1 units | Array |
|
Pt-Co | 10 mm - 5 1/4" | 0 - 500 mg Pt/l | 0.1 mg Pt/l | Array |
|
AOCS-Tintometer Colour (AOCS Cc 13b-45 the Wesson Method, AOCS Cc 8d-55, AOCS Cc 13j-97) | 10 mm - 5 1/4" | 0 - 20 R, 0 - 70 R | 0.1 unit R, 1 unit Y | Array |
|
CIE 94 |
|
||||
CIE L* a* b | dependant on spectral locus | 0.01 | Array |
|
|
CIE L* a* b | 10 mm - 5 1/4" | dependant on spectral locus | 0.01 | Array |
|
CIELAB (L*C*h) | 10 mm - 5 1/4" | L*, C*, dependant on spectral locus, 0 - 360° | 0.01 | Array |
|
Language | Direct Download | |
---|---|---|
Please contact your local Lovibond® representative for details.
Title | Glass Standard Values | Filters | Part Number | Mark as favourite |
---|---|---|---|---|
AOCS-Tintometer Colour |
|
3 | 109720 |
|
AOCS-Tintometer Filter Set |
Approximate Values
|
3 | 136900 |
|
AOCS |
Näherungswert
|
1 | 136980 |
|
FAC |
Approximate values
|
1 | 131043 |
|
FAC Colour |
Approximate Values
|
5 | 139700 |
|
FAC Colour |
Approximate Value
|
4 | 343000 |
|
Gardner |
Approximate Values
|
2 | 342000 |
|
Gardner Colour Filter Set |
Approximate Values
|
4 | 139560 |
|
Gardner |
Approximate values
|
1 | 131041 |
|
Lovibond Red, Yellow, Neutral |
Approximate Value
|
1 | 139592 |
|
Lovibond Red, Yellow, Neutral Filter Set |
Approximate Values
|
5 | 139610 |
|
Lovibond Red, Yellow, Blue Filter Set |
Approximate Values
|
5 | 139620 |
|
Lovibond Red, Yellow, Neutral |
Approximate Values
|
5 | 139630 |
|
Lovibond Red, Yellow, Neutral Filter Set |
Approximate Values
|
5 | 185000 |
|
Lovibond Red, Yellow, Blue |
Approximate Values
|
5 | 186000 |
|
Lovibond Red, Yellow, Neutral Filter Set |
Approximate Values
|
10 | 139590 |
|
Lovibond Red, Yellow, Neutral |
Approximate Values
|
10 | 184000 |
|
Lovibond Red, Yellow, Blue Filter Set |
Approximate Values
|
10 | 187000 |
|
Hazen Colour Filter Set |
Approximate values
|
5 | 139570 |
|
CIE |
Approximate values
|
1 | 131047 |
|