PTV Process Turbidimeters

Next Generation of On-line Turbidity Measurement

Turbidity is the key measurement parameter for determining drinking water quality.  

To develop this instrument, Lovibond® Tintometer® assembled a team of globally recognized turbidity experts.  We tasked them with creating a new process instrument that addresses all of the issues customers struggle with while using their current turbidity systems. These advancements, along with the addition of state-of-the-art communications and user interface make the PTV 1000 and PTV 2000 the next generation of process turbidimeters.

Solutions for Better Workflow: Less Problems, More Benefits
Especially in the low measuring range, on-line process turbidimeters often cause problems. The instruments of the PTV series are designed to provide solutions exactly where most users are struggling in practice. Read here why the PTV 1000 and the PTV 2000 offer benefits above all.
T-CALplus – The New Solution for Cheap Calibration & Verification
Lovibond has developed the T-CALplus® primary standards to simplify the calibration and verification of PTV process turbidimeters. This protected system eliminates many errors known to process turbidity instruments.
Stressed by Complicated Installation & Setup?
No more complicated setup actions and endless installation attempts: Never before has the setup of process turbidimeter been so easy as with the PTV 1000 and PTV 2000. Read here why additional instruments are also a thing of the past.
Bubble Trap & Smart Interface for untroubled controlling
Eliminate annoying bubbles and complicated handling: PTV instruments have many useful innovations that relieve the user and facilitate continuous monitoring of water quality. Learn more about the bubble trap, Smart Interface and other tools that save time and money.
Contact form
Are you interested in our PTV Series and would like more information about the PTV 1000 or PTV 2000? We would be pleased to send you information material about our PTV process turbidimeters or arrange an individual support. We will provide you with a contact person as soon as possible and look forward to your inquiry.
Title Optics Compliance Digital protocol Power Requirements Flow Indicator Part Number Mark as favourite
  • Infrared light

  • ISO 7027
  • 4-20 mA
90 to 264 VAC, 50/60 Hz. Auto Select
  • yes
6124683
  • Infrared light

  • ISO 7027
  • 4-20 mA
90 to 264 VAC, 50/60 Hz. Auto Select
  • yes
6124684
  • Infrared light

  • ISO 7027
  • Modbus RS485/RS232
90 to 264 VAC, 50/60 Hz. Auto Select
  • yes
6124693
  • Infrared light

  • ISO 7027
  • Modbus RS485/RS232
90 to 264 VAC, 50/60 Hz. Auto Select
  • yes
6124694
  • Infrared light

  • ISO 7027
  • 4-20 mA
90 to 264 VAC, 50/60 Hz. Auto Select
  • no
6125683
  • Infrared light

  • ISO 7027
  • 4-20 mA
90 to 264 VAC, 50/60 Hz. Auto Select
  • no
6125684
  • Infrared light

  • ISO 7027
  • Modbus RS485/RS232
90 to 264 VAC, 50/60 Hz. Auto Select
  • no
6125693
  • White LED

  • EPA
  • 4-20 mA
90 to 264 VAC, 50/60 Hz. Auto Select
  • yes
6134683
  • White LED

  • EPA
  • 4-20 mA
90 to 264 VAC, 50/60 Hz. Auto Select
  • yes
6134684
  • White LED

  • EPA
  • Modbus RS485/RS232
90 to 264 VAC, 50/60 Hz. Auto Select
  • yes
6134693
  • White LED

  • EPA
  • Modbus RS485/RS232
90 to 264 VAC, 50/60 Hz. Auto Select
  • yes
6134694
  • White LED

  • EPA
  • 4-20 mA
90 to 264 VAC, 50/60 Hz. Auto Select
  • no
6135683
  • White LED

  • EPA
  • 4-20 mA
90 to 264 VAC, 50/60 Hz. Auto Select
  • no
6135684
  • White LED

  • EPA
  • Modbus RS485/RS232
90 to 264 VAC, 50/60 Hz. Auto Select
  • no
6135693
  • White LED

  • EPA
  • Modbus RS485/RS232
90 to 264 VAC, 50/60 Hz. Auto Select
  • no
6135694
  • Red LED

  • EPA
  • 4-20 mA
90 to 264 VAC, 50/60 Hz. Auto Select
  • yes
6144683
  • Red LED

  • EPA
  • 4-20 mA
90 to 264 VAC, 50/60 Hz. Auto Select
  • yes
6144684
  • Red LED

  • EPA
  • Modbus RS485/RS232
90 to 264 VAC, 50/60 Hz. Auto Select
  • yes
6144693
  • Red LED

  • EPA
  • Modbus RS485/RS232
90 to 264 VAC, 50/60 Hz. Auto Select
  • yes
6144694
  • Red LED

  • EPA
  • 4-20 mA
90 to 264 VAC, 50/60 Hz. Auto Select
  • no
6145683
  • Red LED

  • EPA
  • 4-20 mA
90 to 264 VAC, 50/60 Hz. Auto Select
  • no
6145684
  • Red LED

  • EPA
  • Modbus RS485/RS232
90 to 264 VAC, 50/60 Hz. Auto Select
  • no
6145693
  • Red LED

  • EPA
  • Modbus RS485/RS232
90 to 264 VAC, 50/60 Hz. Auto Select
  • no
6145694
Title Online Download Type Format Language Direct Download
Instruction Manual Process Turbidimeter Instruction Manual PDF (7.96 MB)
Instruction Manual Power & Communications Module Instruction Manual PDF (2.46 MB)
EU-Declaration of Conformity PTV series without Bluetooth Declaration of Conformity PDF (0.19 MB)