In order to give you a better service Tintometer uses cookies. By continuing to browse the site you are agreeing to our use of cookies.

BD 606

Accurate, automatic and direct control of your wastewater samples

Mark as favourite

Part Number 2444465

Highlights

  • User friendly
  • Large brillant graphic display
  • Graphical representation of measured values
  • USB & SD Card interface

The BD 600 is a respirometric system for the determination of Biochemical Oxygen Demand (BOD). Save time, reduce the potential for errors and easily interpret data to help make process control decisions for your plant.

Applications

  • Waste Water Treatment

The BD 600 is the ideal system for process control or as a secondary test to the Dilution Method. Using a respirometric system solves many of the issues associated with the dilution method for BOD analysis.

  • Significantly Reduced Sample Preparation
    It's easy to begin collecting data - simply add sample to the bottle, add nitrification inhibitor and place the sensor head on the bottle. There is no need for sample dilutions or seeding the sample. Because this is a respirometric test, concerns regarding air in the sample are eliminated.
  • Operators do not have to be present at completion of test
    Measurements are automatically taken and stored at regular time intervals and can be recalled at your convenience - no more weekend trips to the lab or plant!  
  • Easy and quick interpretation of measurement values
    In addition to displaying results of a sample directly in mg/l BOD, the large, integrated, display is able to display the BOD curve which makes it is easy to see and understand measurement data points and trends. In addition, each sensor head has an integrated LED. This allows operators to visually confirm which sample the data is being displayed for and reduces potential confusion or errors over which sample data is presented
  • Consistent Measurement Conditions
    The Automatic Start Function ensures all measurements are taken at an equal sample temperature. When the measurement conditions are consistent across readings, operators do not have to work about temperature or pressure fluctuations skewing results.
  • Sample Identification and Tracking
    The BD 600 interface, makes it easy to assign an identification code or sample name when setting up a new sample. This helps track a sample from the time it is collected and ensures traceability during sample measurement.  
  • Use the remote control
    If using an incubator with a glass door, operators can use the supplied remote control to display measurement data for a sample - without even opening the door! This further ensures that samples stay at a consistent temperature which is essential to accurate results.
Display backlit
Interfaces USB
SD-Card
Power Supply 100 - 240 V / 50-60 Hz
3 alkali-manganese batteries (Baby cells/ size C)
Auto – OFF No
Measuring Principle Manometric; mercury-free; electronic pressure sensor
Measuring Range 0-40, 0-80, 0-200, 0-400, 0-800, 0-2000, 0-4000 mg/l
Clock Real Time Clock and Date
Measurement Time User-selectable, between 1 and 28 days
Portability Benchtop
Autostart true
Measuring Stations 12
Compliance CE
EMC according to DIN EN 61326
Protection Class IP 53
Dimensions 181 x 230 x 375 mm
Weight 4.1 kg (4100 g, unit with bottles & batteries 5775 g, complete with stirring unit)
Weight with Packaging (4100 g, unit with bottles & batteries 5775 g, complete with stirring unit)
Title Part Number Mark as favourite
BOD sensor 2444470
Potassium hydroxide solution 45% 2418634
Nitrification inhibitor 2418642
BOD Sample flask, brown glass, 500 ml 418644
6 BOD Sample flasks, brown glass 418645
Rubber gasket 418636
Magnetic stirring rod 418633
Magnetic stirring rod remover 418638
Overflow measuring flask 428 ml 418660
Overflow measuring flask 360 ml 418659
Overflow measuring flask 244 ml 418658
Overflow measuring flask 157 ml 418657
Overflow measuring flask 94 ml 418656
Overflow measuring flask 56 ml 418655
Overflow measuring flask 21,7 ml 418664
Complete Set Overflow measuring flasks 418654
Remote control 2444481
Inductive Stirring Unit 2444456
Test set for checking the system (10 tablets) 2418328
Power supply unit for inductive stirring unit 444454
Y-cable 2444475
USB cable 3 m 2444482
Title Online Download Type Format Language Direct Download
Datasheet 2444465 - BD 606 Datasheet PDF (0.20 MB)
Instruction Manual BD 600 PDF (0.33 MB)
Firmware BD 600 ZIP (1.74 MB)
  • 2 x BD 600 with 12 sensor heads
  • 2 x Control unit with batteries
  • 2 x Power supply unit incl. Y-cable for common power supply of BD 600 and stirring unit
  • 2 x Inductive stirring unit
  • Incl. standard accessory consists of:
    • 12 Sample bottles
    • 12 Rubber gaskets
    • 12 Magnetic stirring rods
    • 50 ml potassium hydroxide solution 45%
    • 50 ml nitrification inhibitor solution
    • 1 Overflow measuring flask 157 ml
    • 1 Overflow measuring flask 428 ml
    • 1 Remote control
    • Manual
    • Guarantee sheet
    • 100 - 240 V / 50 - 60 Hz
The Bluetooth®  word mark is a registered trademark owned by Bluetooth SIG, Inc. and any use by Lovibond® Tintometer GmbH is under license. IOS® is a registered trademark of Cisco, Inc. and licensed to Apple, Inc. Android™ is a trademark of Google, Inc.
Bluetooth®  is a wireless technology subject to regional approval. The use of Lovibond® instruments with Bluetooth® technology is currently only allowed in certain regions of the world. The use of the instruments will also be possible in other regions in the future. For current regions and further information, visit: www.lovibond.com/bluetooth