MD 200 Hydrogen peroxide, pH, liquid reagents
Precise results using high-quality interference filters
- Scroll memory
- Automatic switch-off
- Real-Time-Clock and date
- Calibration mode indicator
Versatile, compact and: The benchtop photometer MD 200 combines high-quality interference filters with long-term stable LEDs as light sources in a high-precision optic. The result: precise measurement results at all times - no matter where you use it.
Part Number 2888102
Applications
- Boiler Water
- Disinfection Control
- Drinking Water Treatment
- Pool Water Control
- Raw Water Treatment
- Waste Water Treatment
Product information
-
Versatile use
The MD 200 photometer can be used in almost all areas of water analysis. -
Precise and low maintenance
The high-precision optics, which in addition to long-term stable LEDs as light sources, also offer high-quality interference filters, ensure precise and reproducible measurement results. In addition, these components make the photometer low-maintenance. -
User friendly
The devices impress with their ease of use, ergonomic design and compact dimensions, which makes handling the devices easy and safe. -
Reagents
Use long-term stable Lovibond® reagent tablets (5-10 years guaranteed minimum durability) or Lovibond® liquid reagents.
Optics | LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used. Wavelength specifications of interference filters: 430 nm Δλ = 5 nm 530 nm Δλ = 5 nm 560 nm Δλ = 5 nm 610 nm Δλ = 6 nm |
Wavelength Accuracy | ± 1 nm |
Photometric Range | -2500 - 2500 mAbs |
Photometric Accuracy | 3 % FS (T = 20 °C – 25 °C) |
Display | backlit LCD (on keypress) |
Interfaces | Infrared |
Operation | Foil keypad |
Auto – OFF | Yes |
Calibration | Factory calibration and user calibration. Reset to factory calibration possible. |
Internal Storage | internal ring memory for 16 data sets |
Power Supply | 4 batteries (AA) |
Battery Life Time | approx. 53 hours |
Clock | Real Time Clock and Date |
Portability | Portable |
Environmental Conditions | temperature: 5 - 40 °C rel. humidity: 30 - 90 % (non condensing) |
Protection Class | IP 68 |
Compliance | CE |
Dimensions | 110 x 55 x 190 mm |
Weight | 455 g |
Testparameter | Measuring Range | Method No. | Chemical Method |
---|---|---|---|
H2O2 HR L | 40 - 500 mg/L H2O2 | M214 | Titanium Tetrachloride / Acid |
H2O2 LR L | 1 - 50 mg/L H2O2 | M213 | Titanium Tetrachloride / Acid |
pH value L | 6.5 - 8.4 pH | M331 | Phenol Red |
Title | Measuring Range | Chemical Method | Packaging Unit | Part Number | Add to quotation cart |
---|---|---|---|---|---|
Reagent for Hydrogen Peroxide | 1 - 50 mg/L H2O2 | Titanium Tetrachloride / Acid | 15 mL | 424991 |
|
Phenol Red Solution | 6.5 - 8.4 pH | Phenol Red | 15 mL | 471040 |
|
Phenol Red Solution | 6.5 - 8.4 pH | Phenol Red | 100 mL | 471041 |
|
Phenol Red Solution in 6-pack | 6.5 - 8.4 pH | Phenol Red | 1 pc. | 471046 |
|
- Instrument in plastic case with 4 batteries (AA)
- 1 Adapter for round cuvettes 16 mm
- 3 Round cuvette with lids, 24 mm
- 3 Round cuvette with lid, 16 mm
- Sealing rings
- 1 Stirring rod
- 1 Brush
- 1 Syringe (10 ml)
- Reagent for Hydrogen Peroxide
- Phenol Red Solution
- Instruction manual
- Manual of Methods
- Certificate (COC)
- Warranty information