PTV Process Turbidimeters

Process Turbidity Simplified

Highlights

  • Optimized for municipal drinking water monitoring 
  • Low maintenance design saves operator's time
  • EPA & ISO options for regulatory compliance
  • Low volume flow body detects changes in turbidity fast

Details Matter. The development of the PTV Series considered every aspect of process turbidity workflow - from installation and setup; daily measurement and control; routine procedures such as calibration, verification and maintenance; to data collection and management. 

The PTV Series is optimized for monitoring filter effluent in a regulatory environment.  By focusing on helping operators manage routine workflows, the instruments deliver an easy to use system with unsurpassed accuracy when monitoring low levels of turbidity.  

Every instrument has an integrated touchscreen display, which makes it easy to see current turbidity values and to assess the status of the instrument.  Outputs and alarm status are always clearly visible, and can alert operators to an issue.   

The flow body is easy to clean - there are no “nooks and crannies” where particles can settle. The body can be easily drained for cleanings or calibrations with quick-connect fixtures and collecting a grab sample for verification does not require the operator to disconnect tubing to access the sample.  The low volume flow body allows changes in turbidity levels to be seen faster than competitive instruments.  

All models feature a solid state light source which means there are no bulbs to change over the life of the instrument.  The optical design has eliminated the chance for condensation and fogging, without the use of desiccants, and there is no risk of fouling the optical system with the presence of iron and manganese.  

The PTV Series also makes it easier than ever to access and analyze data.  Every logged reading, calibration and verification associated with a measurement module over its lifetime is stored locally, ensuring proof of routine data is never deleted or unavailable.  Operators are able to access the information directly from the instrument, so there is no need to locate maintenance logs or pull the data from a SCADA system. 

Title Optics Compliance Digital protocol Power Requirements Flow Indicator Part Number Mark as favourite
PTV 1000 with flow indicator

Infrared light

  • ISO 7027
4-20 mA 90 to 264 VAC, 50/60 Hz. Auto Select yes 6124683
PTV 1000 with flow indicator and Bluetooth

Infrared light

  • ISO 7027
4-20 mA 90 to 264 VAC, 50/60 Hz. Auto Select yes 6124684
PTV 1000 with flow indicator and Modbus

Infrared light

  • ISO 7027
Modbus RS485/RS232 90 to 264 VAC, 50/60 Hz. Auto Select yes 6124693
PTV 1000 with flow indicator, Modbus and Bluetooth

Infrared light

  • ISO 7027
Modbus RS485/RS232 90 to 264 VAC, 50/60 Hz. Auto Select yes 6124694
PTV 1000 basic unit

Infrared light

  • ISO 7027
4-20 mA 90 to 264 VAC, 50/60 Hz. Auto Select no 6125683
PTV 1000 with Bluetooth

Infrared light

  • ISO 7027
4-20 mA 90 to 264 VAC, 50/60 Hz. Auto Select no 6125684
PTV 1000 with Modbus

Infrared light

  • ISO 7027
Modbus RS485/RS232 90 to 264 VAC, 50/60 Hz. Auto Select no 6125693
PTV 1000 with flow indicator

White LED

  • EPA
4-20 mA 90 to 264 VAC, 50/60 Hz. Auto Select yes 6134683
PTV 1000 with flow indicator and Bluetooth

White LED

  • EPA
4-20 mA 90 to 264 VAC, 50/60 Hz. Auto Select yes 6134684
PTV 1000 with flow indicator and Modbus

White LED

  • EPA
Modbus RS485/RS232 90 to 264 VAC, 50/60 Hz. Auto Select yes 6134693
PTV 1000 with flow indicator, Modbus and Bluetooth

White LED

  • EPA
Modbus RS485/RS232 90 to 264 VAC, 50/60 Hz. Auto Select yes 6134694
PTV 1000 basic unit

White LED

  • EPA
4-20 mA 90 to 264 VAC, 50/60 Hz. Auto Select no 6135683
PTV 1000 with Bluetooth

White LED

  • EPA
4-20 mA 90 to 264 VAC, 50/60 Hz. Auto Select no 6135684
PTV 1000 with Modbus

White LED

  • EPA
Modbus RS485/RS232 90 to 264 VAC, 50/60 Hz. Auto Select no 6135693
PTV 1000 with Modbus and Bluetooth

White LED

  • EPA
Modbus RS485/RS232 90 to 264 VAC, 50/60 Hz. Auto Select no 6135694
PTV 1000 with flow indicator, Ethernet and Bluetooth

White LED

  • EPA
Modbus TCP (Ethernet) 90 to 264 VAC, 50/60 Hz. Auto Select yes 6134624
PTV 1000 with flow indicator and Ethernet

White LED

  • EPA
Modbus TCP (Ethernet) 90 to 264 VAC, 50/60 Hz. Auto Select yes 6134623
PTV 1000 with flow indicator and Profibus

White LED

  • EPA
Profibus DP 90 to 264 VAC, 50/60 Hz. Auto Select yes 6134613
PTV 2000 with flow indicator

Red LED

  • EPA
4-20 mA 90 to 264 VAC, 50/60 Hz. Auto Select yes 6144683
PTV 2000 with flow indicator and Bluetooth

Red LED

  • EPA
4-20 mA 90 to 264 VAC, 50/60 Hz. Auto Select yes 6144684
PTV 2000 with flow indicator and Modbus

Red LED

  • EPA
Modbus RS485/RS232 90 to 264 VAC, 50/60 Hz. Auto Select yes 6144693
PTV 2000 with flow indicator, Modbus and Bluetooth

Red LED

  • EPA
Modbus RS485/RS232 90 to 264 VAC, 50/60 Hz. Auto Select yes 6144694
PTV 2000 basic unit

Red LED

  • EPA
4-20 mA 90 to 264 VAC, 50/60 Hz. Auto Select no 6145683
PTV 2000 with Bluetooth

Red LED

  • EPA
4-20 mA 90 to 264 VAC, 50/60 Hz. Auto Select no 6145684
PTV 2000 with Modbus

Red LED

  • EPA
Modbus RS485/RS232 90 to 264 VAC, 50/60 Hz. Auto Select no 6145693
PTV 2000 with Modbus and Bluetooth

Red LED

  • EPA
Modbus RS485/RS232 90 to 264 VAC, 50/60 Hz. Auto Select no 6145694
Title Online Download Type Format Language Direct Download
Instruction Manual Process Turbidimeter Instruction Manual PDF (7.96 MB)
Instruction Manual Power & Communications Module Instruction Manual PDF (2.46 MB)